4.
Check the evacuation (bypass) system for proper operation. Open the
front doors and make sure that the bypass dampers operate properly.
They should seal tightly when the front doors are closed and latched (and
the “Evac” switch, if the pit is equipped with one, is off).
5.
Clean excess carbon build-up or residue from the rear area of the pit,
including the inside of the access door above the firebox, the firebox door
and the area around the firebox door.
DOOR GASKETS
The oven door gasket should be smoke-tight. To stop smoke leaks, you may
need to shim the hinge side, the latch side or both. You may also need to
“thicken” the gasketing by using additional RTV silicone between the gasket and
the body of the unit. Gaskets can be checked with a “paper test”. Insert a strip
of paper so that it is between the door and the gasket and extends outside the
pit. Close and latch the door. Pull the paper towards you. It should be very
resistant to your effort. If it seems loose, further adjust the door or the gasket
thickness.