26
̶
SW-4000M-PMCL
■
When [Exposure Mode] is [Timed]
•
Line Start Trigger Off
Shutter select mode
Data Output
EEN
LVAL
(Blanking)
F (Valid data period)
G (Line Period)
B
D
Set Value + Offset (E)
[Binning Off]
Tap
Geometry
Bit/
Pixel
CL Pixel
Clock
[MHz]
Period From EEN Falling
to LVAL rising [B](usec)
Exposure
offset time
[E](usec)
Data
invalid time
[D](CLK)
Data valid
time [F]
(CLK)
Line Period
[G](CLK)
1X2
8/10
31.70
13.4
-1.2
10
2048
2058
42.41
13.3
-1.2
17
2048
2065
63.39
13.2
-1.2
10
2048
2058
84.82
13.2
-1.2
18
2048
2066
1X3
8
31.70
13.4
-1.2
7
1364
1371
42.41
13.3
-1.2
12
1364
1376
63.39
13.2
-1.2
8
1364
1372
84.82
13.2
-1.2
12
1364
1376
1X4
8/10
31.70
13.4
-1.2
5
1024
1029
42.41
13.3
-1.2
9
1024
1033
63.39
13.2
-1.2
6
1024
1030
84.82
13.2
-1.2
10
1024
1034
1X8
8/10
31.70
13.4
-1.2
3
512
515
42.41
13.3
-1.2
5
512
517
63.39
13.2
-1.2
4
512
516
84.82
13.2
-1.2
6
512
518
1X10
8
31.70
13.4
-1.2
3
409
412
42.41
13.3
-1.2
4
409
413
63.39
13.2
-1.2
3
409
412
84.82
13.2
-1.2
52
409
461