Page 40
TS-2030EN/TS-2076EN Series Progressive Scan Cameras
Camera Features
TABLE 8.
Gain Table (Color EN Camera)
Note: Gain Value is Gain entry in camera LUT after calibration.
When the EN camera is controlled by a light sensor, user can monitor the gain value in the EN setup software by
accessing "Camera Gain" status register (Address = 232). This Gain value is the Gain Table Entry in LUT after
calibration (left side of the table above).
6.4 Flash/Nighttime Light Control
The strobe and continuous nighttime light controls are critical at nighttime. ADR (Automatic Dynamic Range)
control inside the EN automatically turns on and off the strobe and night light based on the output from the light
sensor. The user can manually turn on and off the strobe and night light if necessary. You need to be able to
access the following registers by means of the EN setup software.
Register Address 10: Night Light Control
Register Address 11: Night Light ON threshold and Flash enable. Register Address 12: Night Light OFF
threshold and Flash enable. Register Address 50: Camera ADR Control
The distance and angle of the strobe unit toward the target is critical and must be optimized. Please refer to the
VIS400 Installation Manual for more information.
6.5 External Control
6.5.1
RS-485
The TS-2030EN/TS-2076EN has the ability to connect multiple cameras on the same RS-485 network. Each
camera has an individual ID number selectable via control registers; Camera RS-485 group register
Gain Value
dB
0
11.8
22
13.4
46
15.1
74
17.0
105
19.2
140
21.7
165
23.4
192
25.5
226
27.8
255
27.7
Summary of Contents for Pulnix TS-2030EN Series
Page 1: ...TS 2030EN TS 2076EN Series Progressive Scan Cameras 10490 Rev A See the possibilities ...
Page 2: ...Page ii ...
Page 4: ...Page iv ...
Page 8: ...Page viii Table of Contents ...
Page 10: ...Page x List of Figures ...
Page 12: ...Page xii List of Tables ...
Page 66: ...Page 54 TS 2030EN TS 2076EN Series Progressive Scan Cameras Appendix ...
Page 67: ...Page 55 ...