IIT Camera System Manual
32
System Set-Up
Figure 30.
IIT I/O Board communication
The DAC values in
commands C to J
are set to 32 from the factory and it is normally not necessary
to change these.
The TTL Trigger pulse width is set by
command A
to a value between 01 and FF (255d) times 0.1
ms. = between 0.1 and 25.5ms. Factory setting is 1ms.
The minimum time between two trigger pulses are set by
command M
to a value between 01 and FF
(1-255ms).
The number of consecutive samples being high from a passing license plate is set by the
command
X
. The factory setting is 06 and the unit is 0.2ms. The setting applies to all 8 fiber channels.
The number of consecutive samples being low between two passing license plates is set by the
command Y
. Factory setting is 0A and the unit is 0.2ms.
In Appendix F is found a list of all default settings for the IIT I/O Board.