background image

Thank you for purchasing this product. 
           Be sure to read this manual before use.

This manual includes important safety precautions and instructions on how to operate the unit. Be sure to read this manual to ensure proper operation. 
The contents of this manual are subject to change without notice for the purpose of improvement.
@2021 JAI

  

CMOS Digital Progressive Scan

Monochrome and Color Camera 

Document Version: 0.1

GO-X_Series_RollingShutter_PGE_Ver.0.1_Sep2021

GOX-6409M-PGE / GOX-6409C-PGE

GOX-12409M-PGE / GOX-12409C-PGE

GOX-20409M-PGE / GOX-20409C-PGE

User Manual

PRELIMINARY

Summary of Contents for GOX-6409M-PGE

Page 1: ...ad this manual to ensure proper operation The contents of this manual are subject to change without notice for the purpose of improvement 2021 JAI CMOS Digital Progressive Scan Monochrome and Color Ca...

Page 2: ...the Camera and PC 17 Step 5 Changing the Camera Settings 20 Step 6 Adjusting the Image Quality 21 Step 7 Saving the Settings 24 Main Functions 25 Sensor Shutter Mode 25 Acquisition Control 27 Exposur...

Page 3: ...mageFormatControl 54 AcquisitionControl 56 EventControl 57 AnalogControl 58 DigitalIOControl 59 PulseGenerator 60 LUTControl 61 TestControl 61 TransportLayerControl 61 ActionControl 62 UserSetControl...

Page 4: ...ecord 77 Index 78 About Technical Note Some additional technical information is provided on the JAI website as Technical Notes In this manual if a technical note is available for a particular topic th...

Page 5: ...CISPR32 2015 EN 55035 2017 CISPR35 2016 FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are design...

Page 6: ...ted to the regulation on Measures for the Administration of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camer...

Page 7: ...ted to the regulation on Measures for the Administration of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camer...

Page 8: ...Never use your hands or cloth blow with your mouth or use other methods to remove dust Phenomena specific to CMOS image sensors The following phenomena are known to occur on cameras equipped with CMOS...

Page 9: ...cluding external trigger exposure setting image level control look up table shading correction blemish compensation ROI binning etc In addition these cameras feature the backside illumination technolo...

Page 10: ...pe adapter etc here Before mounting a lens be sure to refer to Step 2 Connecting Devices and confirm the precautions for attaching a lens and the supported lens types RJ 45 connector Connect a Gigabit...

Page 11: ...ternal trigger LINK LED Indicates whether the GigE network connection is established or not ACT LED Indicates the GigE network status DC IN TRIG connector 6 pin round Connect the cable for a power sup...

Page 12: ...ision I F Preliminary 12 Recommended external input circuit diagram reference example Recommended external output circuit diagram reference example OPTO In circuit characteristics Opto In Pin2 Opto In...

Page 13: ...that should be used The response speed from On High to Off Low depends on the voltage applied to Opto output and the value of the load resistance Higher load resistance results in slower response If t...

Page 14: ...Settings Refer to the procedure for changing the output format setting as an example and change various settings as necessary Step 6 Adjusting the Image Quality Refer to the procedures for adjusting t...

Page 15: ...vignetting and to obtain the optimal resolution use a lens that will cover the image sensor size Model name Image Sensor GOX 6409M PGE Mono 1 1 8 inch 7 37 mm x 4 91 mm 8 86mm diagonal GOX 6409C PGE C...

Page 16: ...ble to the RJ 45 connector Use a LAN cable that is Category 5e or higher Category 6 recommended Use a LAN cable that is STP cable When supplying power via PoE connect to a PoE compatible switching hub...

Page 17: ...the POWER TRIG LED lights green Verify whether power is being supplied to the camera by checking the rear LED For details on how to read the LEDs see LED status and camera status in the Parts Identifi...

Page 18: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 18 2 Select the camera you want to configure Click the Select Connect button The connected camera is listed Please select one camera...

Page 19: ...camera are displayed Click the Device control button The screen shown below will be displayed In this window you can adjust various settings of the camera This completes the procedure for verifying w...

Page 20: ...tings are as follows Change the settings as necessary Factory default values GOX 12409C PG Item Default value ImageFormatControl Width 4016 Height 3036 OffsetX horizontal position 0 OffsetY vertical p...

Page 21: ...When a time consuming process such as white balance is performed this camera returns an Ack response when the process is completed In this case some camera control software may cause a timeout error w...

Page 22: ...Auto is set to Off by default 2 Configure the Gain Expand AnalogControl and select the gain you want to configure in GainSelector AnalogAll master gain DigitalRed digital R gain and DigitalBlue digita...

Page 23: ...white cloth or wall can also be used Be sure to prevent the high intensity spot lights from entering the screen 2 Select the BalanceWhiteAuto tab and select Continuous or Once for the adjustment metho...

Page 24: ...tination UserSet1 to UserSet3 in UserSetSelector Note The factory default setting values are stored in Default and cannot be overwritten Caution Settings can only be saved when image acquisition on th...

Page 25: ...hen Rolling is selected each pixel row is exposed at a different timing when Global Reset is selected each pixel row is exposed at the same time Rolling Use Rolling for applications with static object...

Page 26: ...r more information see the ExposureActive Signal section ExposureActive Signal When SensorShutterMode is set to Global Reset control the strobe flash timing using the ExposureActive signal Start the f...

Page 27: ...ed the number of frames set in AcquisitonFrameCount are acquired as images Continuous When the AcquisitionStart command is executed images will continue to be acquired until the AcquisitionStop comman...

Page 28: ...0 49 Hz Approx 2 04 seconds Related Setting Items AcquisitionControl Exposure Mode This camera has two Exposure modes Off Timed Use the AcquisitionControl settings to perform operations and settings f...

Page 29: ...m maximum exposure time vary depending on the model and various settings as shown in the table Model Name Sensor Shutter Mode Pixel Format Exposure Offset us Min Exposure Time Setting us Max Exposure...

Page 30: ...to configure the settings described in ExposureMode You can delay when exposure actually starts after a trigger is received by a specific amount of time by configuring TriggerDelay Select the trigger...

Page 31: ...C PGE Color model BayerRG8 GOX 12409M PGE GOX 20409M PGE Monochrome model Mono8 Mono10 Mono10Packed Mono12 Mono12Packed GOX 12409C PGE GOX 20409C PGE Color model BayerRG8 BayerRG10 BayerRG10Packed Bay...

Page 32: ...eFormat LineInverter LineStatusAll Line2 Output OptoCoupled True False bit1 DC IN TRIG IN connector 6 pin round Line5 Input OptoCoupled False fixed bit4 DC IN TRIG IN connector 6 pin round Nand0In1 In...

Page 33: ...e Gain AnalogGain BlemishCompensation Related Setting Items ImagingControl Calculate the Maximum Frame Rate Approximate This section describes how to calculate the maximum frame rate approximate Note...

Page 34: ...1 GOX 12409MC PGE Mono8 Bayer8 19 338 Mono10 Mono12 Bayer10 Bayer12 Mono10Packed Bayer10Packed Mono12Packed Bayer12Packed 22 94 GOX 20409MC PGE Mono8 Bayer8 25 96 Mono10 Mono12 Bayer10 Bayer12 Mono10P...

Page 35: ...ExposureProhibitPeriod Model SensorShutter Mode V_Sync_TrigOn H ExposureProhibit Period H GOX 6409MC PGE Rolling 2111 8 GlobalReset 2111 0 GOX 12409MC PGE Rolling 3081 8 GlobalReset 3081 0 GOX 20409MC...

Page 36: ...atic Gain Level Control Set GainAuto to Continuous to control the gain level automatically When GainAuto is set to Continuous you can configure the conditions for automatic adjustment in detail When G...

Page 37: ...hMidRight HighRight MidHighLeft MidHighMidLeft MidHighMidRight MidHighRight MidLowLeft MidLowMidLeft MidLowMidRight MidLowRight LowLeft LowMidLeft LowMidRight LowRight In addition the white balance ha...

Page 38: ...ontrolALC The target video levels for AGC and ASC are configured in ALCReference For example when ALCReference is set to 95 video levels will be maintained at 95 using AGC and ASC In color models the...

Page 39: ...ay be less noticeable when camera outputs are displayed without processing The Gamma function can be used to correct the camera signals with an opposite direction curve and produce a display that is c...

Page 40: ...LUT Use LUT LUTSelector Red Green Blue Select the LUT channel to control LUTIndex 0 256 Select the LUT index to configure Indexes represent the possible pixel values captured on the sensor from the lo...

Page 41: ...lit defective pixels i e white blemishes 1 Shield the camera sensor If a lens is attached use the lens cap as a shield for example 2 Configure the threshold level for defective pixel detection Up to 2...

Page 42: ...xel points for interpolation using the BlemishCompensationPositionX and BlemishCompensationPositionY settings You can configure values that are within the total effective pixel area Specify pixels for...

Page 43: ...usting the brightness levels of the other areas to match this level ColorShading Color Model Only R channel and B channel properties are adjusted to using the G channel shading properties as a referen...

Page 44: ...in ShadingMode Related Setting Items ShadingControl Binning Function Monochrome models only The Binning function allows you to combine the signal values of clusters of adjacent pixels to create improv...

Page 45: ...inning On 48 to B step 8 A GOX 6409MC PGE 3088 GOX 12409MC PGE 4016 GOX 20409MC PGE 5472 B GOX 6409M PGE 1544 GOX 12409M PGE 2008 GOX 20409M PGE 2736 V Binning Off 8 to C step 2 V Binning On 4 to D st...

Page 46: ...seGeneratorPulseWidth 4 PulseGeneratorClearSyncMode AsyncMode The table below shows the PulseGeneratorClearSource signals that can be set LineSelector Off AcquisitionActive FrameActive ExposureActive...

Page 47: ...era Counter0 Counter1 Counter2 and Counter3 The functions that can be counted are fixed for each counter Counter0 Counts the number of FrameTrigger Counter1 Counts the number of ExposureStart Counter2...

Page 48: ...nter 0 3 Select the counter CounterEventSource Counter0 Off Frame Trigger Counter1 Off ExposureStart Counter2 Off SensorReadOut Counter3 Off FrameTransferEnd Select the counter event signal for which...

Page 49: ...t ChunkModeActive to True Caution The Chunk Data function settings cannot be changed during image output To change the settings stop Acquisition Related Setting Items ChunkDataControl Event Control Fu...

Page 50: ...f the Camera 1 Specify ActionDeviceKey 2 Then specify two actions that can be configured on the camera Action1 Select 1 in ActionSelector Specify ActionGroupMask ActionSelector Specify ActionGroupKey...

Page 51: ...for synchronization Time synchronization is performed Frequency tuning is not performed PTP time data 80 bit elapsed time in 1 ns with 00 00 00 January 1 1970 set as the origin Timestamp this camera...

Page 52: ...exist Instance Example When the analog gain can be changed for each of the red green and blue channels in a color camera Analog gain is a function that has multiple instances and red green and blue a...

Page 53: ...0000000 step 1000 3000000 Set the timeout of Heartbeat unit s DeviceStreamChannelCount DeviceEventChannelCount DeviceCharacterSet DeviceReset DeviceRegistersEndianness DeviceTemperatureSelector Mainbo...

Page 54: ...824 Display the maximum image height Monochrome model This value will vary depending on the VerticalBinning setting Width Set the image width BinningHorizontal 1 GOX 6409MC PGE 96 3088 step 16 GOX 124...

Page 55: ...se False Reverse pixels vertically GOX 6409MC PGE model only PixelFormat monochrome model 0x01080001 Mono8 color model 0x01080009 BayerRG8 Set the pixel format GOX 6409M PGE 0x01080001 Mono8 GOX 6409C...

Page 56: ...e 0 Low 1 High 2 Software 10 PulseGenerator0 14 17 UserOutput0 3 18 19 Action0 1 21 Line5 Opt In1 26 Nand0 Out 27 Nand1 Out 21 Line5 Opt In1 Select the trigger signal source TriggerActivation 1 Rising...

Page 57: ...FrameStart Display the EventID 9300h EventFrameStartTimestamp Displays the Timestamp value when an event occurs EventFrameStartFrameID The FrameID value at the time of the event is displayed EventFram...

Page 58: ...Left 3 Low Left 4 Mid Low Right 5 Mid Low Mid Right 6 Mid Low Mid Left 7 Mid Low Left 8 Mid High Right 9 Mid High Mid Right 10 Mid High Mid Left 11 Mid High Left 12 High Right 13 High Mid Right 14 Hi...

Page 59: ...utput signal LineStatus True False Display the status of the input signal or output signal True High False Low LineMode Input Output Display the input output status whether it is input or output LineF...

Page 60: ...milliseconds When the counter reaches this value the output will be 1 The setting range varies depending on the ClockPreScaler value PulseGeneratorStartPoint 1 PulseGeneratorClock PulseGeneratorStartP...

Page 61: ...ion StreamChannel0AllInTransmission StreamChannel0UnconditionalStreaming StreamChannel0ExtendedChunkData pGevSupportedOptionSelectorValue GevSupportedOption True False Display whether support for the...

Page 62: ...It can be used by the application to prevent IP fragmentation of packets on the stream channel GevSCPSPacketSize B 1476 12036 step 4 1476 This GigE Vision specific feature corresponds to DeviceStreamC...

Page 63: ...ffsetX ChunkID 2000h DataType Integer ChunkOffsetY The value of OffsetY ChunkID 2001h DataType Integer ChunkWidth The value of Width ChunkID 2002h DataType Integer ChunkHeight The value of Height Chun...

Page 64: ...C according to the individual enabled disabled photometry area states configured in ALCAreaSelector ALCControlRatio 1 100 90 Set the response speed 100 is the fastest AutoShutterControlExposureMin 100...

Page 65: ...You can also manually enter the X coordinate of the blemish you want to correct BlemishCompensationPositionY GOX 6409MC PGE 1 2063 GOX 12409MC PGE 1 3035 GOX 20409MC PGE 1 3647 1 Display the Y coordin...

Page 66: ...to read the count value to a dedicated counter and read the value CounterEventActivation Set the count timing The setting value is fixed with the following data Counter0 RisingEdge Counter1 RisingEdg...

Page 67: ...not noticeable Use the gamma function to correct the display As the light emitting properties of the monitor are not linear the entire image may be darker or the gradation in the dark areas may be le...

Page 68: ...ked Frame Rate 3 8 fps Bright SN GOX 6409MC PGE 0dB 222LSB 8bit GOX 12409Mc PGE 0dB 890LSB 10bit GOX 20409Mc PGE 0dB 890LSB 10bit 38 dB 36 dB Gch image size effective image GOX 6409MC PGE 1 1 8 inch 7...

Page 69: ...9MC PGE 0 2018 step 2 GOX 12409MC PGE 0 3028 step 2 GOX 20409MC PGE 0 3640 step 2 Binning H 1 GOX 6409MC PGE 3088 GOX 12409MC PGE 4016 GOX 20409MC PGE 5472 2 GOX 6409MC PGE 1544 GOX 12409MC PGE 2008 G...

Page 70: ...it DigitalBlue 64 64 LSB 12bit Resolution adjustment 1LSB 12bit Gain adjustment Manual adjustment range AnalogAll 0dB 42dB GOX 6409MC PGE 0db 24db GOX 12409MC PGE GOX 20409MC PGE DigitalRed 7dB 15dB D...

Page 71: ...perature humidity 25 60 20 80 non condensing Regulations CE EN 55032 2015 and EN 55035 2017 FCC class A part 15 RoHS WEEE Dimensions housing 29 29 41 5 mm WHD excluding mount protrusions Weight 65 g P...

Page 72: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 72 Spectral Response GOX 6409MC PGE...

Page 73: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 73 Spectral Response GOX 12409MC PGE...

Page 74: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 74 Spectral Response GOX 20409MC PGE...

Page 75: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 75 Dimensions...

Page 76: ...891 0 1 1 1 122 2 1 259 3 1 413 4 1 585 5 1 778 6 1 995 7 2 239 8 2 512 9 2 818 10 3 162 11 3 548 12 3 981 13 4 467 14 5 012 15 5 623 16 6 31 17 7 079 18 7 943 19 8 913 20 10 21 11 22 22 12 589 23 14...

Page 77: ...al JAI distributor Trademarks Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries Intel and Intel Core are trademarks of Int...

Page 78: ...r 11 Digital Input Output Settings 32 Dimensions 75 Exposure Mode 28 Feature Properties 53 Frame Rate 33 Gamma Function 39 GPIO 32 LED 11 Lens 15 Lens mount 10 Lookup Table 40 LUT 40 Parts Identificat...

Page 79: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 79 Revision History Revision Date Changes 0 1 Sep 2021 Preliminary Version...

Reviews: