Go-X Series Rolling Shutter GigE Vision I/F (Preliminary)
39
Gamma Function
The Gamma function corrects the output signals from the camera beforehand (reverse correction),
taking into consideration the light-emitting properties of the monitor display. As the light-emitting
properties of the monitor are not linear, the entire image may be darker or the gradation in the
dark areas may be less noticeable when camera outputs are displayed without processing.
The Gamma function can be used to correct the camera signals with an opposite-direction curve
and produce a display that is close to linear.
To Use the Gamma Function
Configure the settings as follows.
Item
Setting Value / Selectable Range
Description
Gamma
0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8,
0.9, 1.0
Select the Gamma correction
value.
LUTMode
Gamma
Use Gamma.
Note
: You can use the LUT function to configure a curve with more detailed points. For details, see
Related Setting Items
Summary of Contents for GOX-6409M-PGE
Page 72: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 72 Spectral Response GOX 6409MC PGE...
Page 73: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 73 Spectral Response GOX 12409MC PGE...
Page 74: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 74 Spectral Response GOX 20409MC PGE...
Page 75: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 75 Dimensions...