User Manual (Ver.1.4) - Setting List
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 135 -
Analog Control Item
Setting Range
Default
Value
Description
AWBAreaSelector
-
0: Low
Right
Select the area for which to configure AWBAreaEnable.
Note:
Color models only.
0: Low Right
1: Low Mid-Right
2: Low Mid-Left
3: Low Left
4: Mid-Low Right
5: Mid-Low Mid-Right
6: Mid-Low Mid-Left
7: Mid-Low Left
8: Mid-High Right
9: Mid-High Mid-Right
10: Mid-High Mid-Left
11: Mid-High Left
12: High Right
13: High Mid-Right
14: High Mid-Left
15: High Left
AWBAreaEnable
0: False
1: True
1: True
Enable/disable the photometry area selected in AWBAreaSelector.
AWBAreaEnableAll
0: False
1: True
1: True
True: Operate BalanceWhiteAuto with all areas designated as photometry areas,
regardless of the individual enabled/disabled photometry area states configured
in AWBAreaSelector.
False: Operate BalanceWhiteAuto according to the individual enabled/disabled
photometry area states configured in AWBAreaSelector.
AWBControlSpeed
1
~
8
4
Set the response speed for BalanceWhiteAuto. (8 is the fastest)
BalanceWhiteAutoResult
-
0: Idle
Display the results of BalanceWhiteAuto.
0: Idle
1: Processing
2: Converging
3: Succeeded
4: Error1 - G image was too bright
5: Error2 - G image was too dark
6: Error3 - Timeout
7: Error4 - could not processing
8: Error5 - R or B image was out of range