User Manual (Ver.1.4) - Setting List
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 131 -
Digital IO Control
Item
Setting
Range
Default
Value
Description
LineStatusAll
-
-
Display the input/output signal status. The state is shown with 16 bits. Bit
assignments are as follows.
bit0: Unused (Fixed to 0)
bit1: Line2
bit2 - 3: Unused (Fixed to 0)
bit4: Line5
bit5: Unused (Fixed to 0)
bit6: Line7
bit7 - 15: Unused (Fixed to 0)
OptInFilter (ns)
0
~
40000000
0
Remove noise from the OptIn input signal of Digital I/O. Step: 100
Setting Range:
0
~
40ms
UserOutput
Selector
-
0: User
Output 0
Set the UserOutput signal.
0: User Output 0
1: User Output 1
2: User Output 2
3: User Output 3
UserOutput
Value
0: False
1: True
0: False
Set the value for the UserOutput selected in UserOutputSelector.