Go-X Series Rolling Shutter GigE Vision I/F (Preliminary)
60
PulseGenerator
Configure pulse generator settings.
Item
Setting range
Default value
Description
ClockPreScaler
1
~
4096
GOX-6409MC-PGE: 4
GOX-12409MC-PGE: 9
GOX-20409MC-PGE: 9
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
PulseGeneratorClock (MHz)
GOX-6409MC-PGE:
0.0181274
~
74.25
GOX-12409MC-PGE:
0.017624 ~ 72.188
GOX-20409MC-PGE:
0.017624 ~ 72.188
GOX-6409MC-PGE:
18.5625
GOX-12409MC-PGE:
8.02089
GOX-20409MC-PGE:
8.02089
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
PulseGeneratorSelector
PulseGenerator0
PulseGenerator0
Select the pulse generator.
PulseGeneratorLength
1
~
1048575
GOX-6409MC-PGE:
618750
GOX-12409MC-PGE
:
267363
GOX-20409MC-PGE:
267363
Set the maximum count-up value as a clock count.
PulseGeneratorLengthMs (ms)
1 / PulseGeneratorClock
(MHz)
~
1048575 /
PulseGeneratorClock (MHz)
33.3333
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz)
÷ 1048575 x 1000000
~
PulseGeneratorClock (MHz) x
1000000
30
Set the maximum count-up value as a frequency.
This value is calculated using the [PulseGeneratorLength] value as a base.
PulseGeneratorStartPoint
0
~
1048574
0
Set the start point of the High interval as a clock count.
When the counter reaches this value, the output will be 1.
PulseGeneratorStartPointMs
(ms)
0
~
1048575 /
PulseGeneratorClock (MHz)
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorStartPoint = 1/PulseGeneratorClock *
PulseGeneratorStartPointValue
PulseGeneratorEndPoint
1
~
1048575
GOX-6409MC-PGE:
464063
GOX-12409MC-PGE:
200522
GOX-20409MC-PGE:
200522
Set the start point of the Low interval as a clock count.
When the counter reaches this value, the output will be 0.
PulseGeneratorEndPointMs (ms)
1/ PulseGeneratorClock
(MHz)
~
1048575 /
PulseGeneratorClock (MHz)
25
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorStartPointMs=1/PulseGeneratorClock * PulseGeneratorStartPoint
PulseGeneratorPulseWidth (ms)
ー
25
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting range varies
depending on the [ClockPreScaler] value.
PulseGeneratorPulseWidth = (1/(PulseGeneratorClock * 1000)) *
(PulseGeneratorEndPoint - PulseGeneratorStartPoint)
PulseGeneratorRepeatCount
0
~
255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is enabled with no repeat limit.
PulseGeneratorClearActivation
0: Off
1: HighLevel
2: LowLevel
3: RisingEdge
4: FallingEdge
Off
Set the clear signal condition for the count clear input of the pulse generator.
PulseGeneratorClearSource
ー
Low
Select the count clear input signal source.
[Setting range]
0:Low, 1:High, 3:AcquisitionTriggerWait, 4:AcquisitionActive, 5:FrameTriggerWait,
6:FrameActive, 7:ExposureActive, 8
:
FVAL, 14-17:UserOutput0-3, 18:Action1, 19:Action2,
21:Line5 Opt In1, 26:Nand0 Out, 27:Nand1 Out
PulseGeneratorClearSyncMode
0:Async Mode
1:Sync Mode
0:Async Mode
Select the sync mode for the count clear input signal.
Summary of Contents for GOX-12409C-PGE
Page 72: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 72 Spectral Response GOX 6409MC PGE ...
Page 73: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 73 Spectral Response GOX 12409MC PGE ...
Page 74: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 74 Spectral Response GOX 20409MC PGE ...
Page 75: ...Go X Series Rolling Shutter GigE Vision I F Preliminary 75 Dimensions ...