User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 57 -
1x2-1Y (1 Line Clock, Horizontal Frequency/Period)
Horizontal Timing (Continuous Trigger Mode) (2/2)
Note:
A: Operation Value; B = Calculation Value
Camera Settings
A: Operation value B: Calculation value
Tap
Geometry
Camera Link
Pixel Clock
ROI
Binning
1 line Total
clock (Unit:
clock)
Horizontal
Frequency (Unit:
kHz)
Horizontal
Period (Unit:
us)
Width
Offset
X
Height
Offset
Y
Horizontal Vertical
1X2 - 1Y
84.99 MHz
2560
0
2048
0
Off
Off
A
1293.7
65.703
15.22
B
1294
65.668
15.224
1280
0
2048
0
x2
Off
A
656.2
129.534
7.72
B
657
129.376
7.729
640
0
2048
0
x4
Off
A
574.6
147.929
6.76
B
575
147.826
6.765
2560
0
1024
0
Off
x2
A
1293.7
65.703
15.22
B
1294
65.668
15.224
1280
0
1024
0
x2
x2
A
656.2
129.534
7.72
B
657
129.376
7.729
640
0
1024
0
x4
x2
A
574.6
147.929
6.76
B
575
147.826
6.765
2560
0
512
0
Off
x4
A
1293.7
65.703
15.22
B
1294
65.668
15.224
1280
0
512
0
x2
x4
A
656.2
129.534
7.72
B
657
129.376
7.729
640
0
512
0
x4
x4
A
574.6
147.929
6.76
B
575
147.826
6.765