User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 30 -
3. If you use 80-bit (8-tap/10-bit) camera configuration, DVAL and Exposure Active (JAI
custom) are not output through the Camera Link interface. FVAL is only output via Digital
I/O-1 connector.
Camera Link Pixel Clock Frequency
Related Setting Items:
On this camera, the Camera Link pixel clock can be selected from 84.99 MHz, 72.85 MHz, 58.28 MHz,
and 48.57 MHz. If the 48.57MHz clock is used, the transfer length through the camera link cable will be
extended to 10m for all tap geometries. On the other hand, the frame rate will be reduced (see table).
The default setting is 72.85 MHz.
Camera Link
Pixel Clock
Maximum
Length
1X2-1Y
1X3-1Y
1X4-1Y
1X8-1Y
8 / 10 / 12bit
8bit
8 / 10 / 12bit
8bit
10bit
High (84.99 MHz)
5m
31.9
47.8
63.6
-
-
Mid (72.85 MHz)
5m
27.4
41.0
54.7
-
-
High (72.85 MHz)
10m
-
-
-
107.2
-
Mid (58.28 MHz)
10m
-
-
-
-
84.9
Low (48.57 MHz)
10m
18.3
27.4
36.4
70.8
70.8
Note:
The maximum lengths shown in the above table are guidelines. Operating at these lengths
may generate bit noise, depending on the cable used.