— 36 —
GO-5000M-PMCL-UV
Acquisition control
With Trigger OFF (free running mode), the default frame rate of the camera is based on the
specified ROI. The smaller the ROI, the faster the default frame rate. However, it is possible to
specify a free-running frame rate (i.e., no trigger needed) that is slower than the default rate.
This can be useful when a longer exposure time is needed for a specific ROI.
Modification of the frame rate is done by entering a value in the AcquisitionFrameRate control
corresponding to the frame frequency (Hz). Allowed values range from the shortest frame rate to
0.125Hz (fps), however if the value entered is less than the time required for the default frame
rate, the setting is ignored and the default frame rate is used.
The setting range in Acquisition Frame Rate is:
Calculation of the frame rate
The frame rate depends on the tap geometry and is calculated in the following formula.
Maximum Frame Rate (fps) = 1/(Rounddown
*3
([Trow]x16/C) x ([H]+E) x 0.988
*4
) x 1000000
Where,
[Trow]=Roundup
*1
((Roundup
*1
(2560 /A
*2
) x [W] /2560 + B) x A
*2
) x C /(Dx16)
If the result of the calculation is equal or less to 164, [Trow] is fixed to 164.
Binning OFF: [W] = [Width
*5
], [H] = [Height
*6
]
Binning ON: [W] = [Width
*5
] + 1, [H] = [Height
*6
]
Figures for A to E by the tap geometry.
The following table shows Width and Height in the binning modes.
*1 Roundup after the decimal point
*2 Number of TAP
*3 Round down after the decimal point
*4 Compensation coefficient
*5 Refer to the width value on the above table.
*6 Refer to the height value on the above table.
*7 Maximum frame rate at the full image size
Summary of Contents for GO-5000M-PMCL-UV
Page 17: ... 17 Main Functions Camera Link Interface GO 5000M PMCL UV ...
Page 26: ...1X8 1Y 1X8 1Y is an 8 tap readout system and outputs as follows 26 GO 5000M PMCL UV ...
Page 28: ... 28 GO 5000M PMCL UV ...
Page 29: ... 29 GO 5000M PMCL UV ...
Page 30: ... 30 GO 5000M PMCL UV ...
Page 31: ... 31 GO 5000M PMCL UV ...
Page 33: ...GO 5000M PMCL UV 33 ...
Page 34: ...GO 5000M PMCL UV 34 ...
Page 49: ...Operation and function matrix 49 GO 5000M PMCL UV ...
Page 56: ... 56 External appearance and dimensions GO 5000M PMCL UV ...
Page 57: ... 57 GO 5000M PMCL UV Spectral response ...
Page 64: ... 64 GO 5000M PMCL UV Acquisition Control ...
Page 65: ... 65 GO 5000M PMCL UV Digital I O Control Analog Control LUT Control Transport Layer Control ...
Page 66: ... 66 GO 5000M PMCL UV User Set Control JAI Custom ...
Page 67: ... 67 GO 5000M PMCL UV ...
Page 68: ... 68 GO 5000M PMCL UV ...
Page 69: ... 69 GO 5000M PMCL UV ...
Page 70: ... 70 GO 5000M PMCL UV ...
Page 71: ... 71 GO 5000M PMCL UV ...
Page 72: ... 72 GO 5000M PMCL UV ...
Page 74: ... 74 Revision Date Changes Revision history 1 0 Feb 2021 1st Draft GO 5000M PMCL UV ...