User Manual (Ver. 1.0) - Short ASCII Command List
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 98 -
Technology Specific Bootstrap Register
Related Topic:
Name
Access
Short
ASCII
Values
MIN MAX Default
Description
SupportedBaud
rates
R/O
SBDRT
Indicate Support/Non-
support status for each
baud rate
bit0: 9600bps
bit1: 19200bps
bit2: 38400bps
bit3: 57600bps
bit4: 115200bps
0x01 0xFF
0x1F
SBDRT?<CR><LF>
CurrentBaudrate R/W
CBDRT
READ
: Indicate current
baud rate.
WRITE
: Set any bit of
baud rate.
bit0: 9600bps
bit1: 19200bps
bit2: 38400bps
bit3: 57600bps
bit4: 115200bps
0x01 0x80
1
(9600bps)
CBDRT=[Param.]<CR><LF>
CBDRT?<CR><LF>
In case of WRITE execution (change baud
rate), it needs to control in the proper
sequence between Host and Camera.
Device Control
Name
Interface
Access
Short ASCII
Values
Default
Description
DeviceFirmware Version
R/O
VN
Firm Ver. No.
-
VN?<CR><LF>
DeviceReset
W/O
CRS00
1
-
CRS00=1<CR><LF>