![JAI GO-5000M-PMCL-1 User Manual Download Page 26](http://html1.mh-extra.com/html/jai/go-5000m-pmcl-1/go-5000m-pmcl-1_user-manual_3281399026.webp)
User Manual (Ver. 1.0) - Preparation
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 26 -
Save the User Settings
1. Stop image acquisition. Settings can only be saved when image acquisition on the camera is
stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the
UserSetSave
command and save
the current camera settings.
Item
Short ASCII
Command
Values
Command Examples
UserSetSave
SA
1: User1
2: User2
3: User3
SA=[Param.]<CR><LF>
SA?<CR><LF>
Load the User Settings
1. Stop image acquisition. User settings can only be loaded when image capture on the camera is
stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the
UserSetLoad
command and read
the settings of the camera.
Note:
When selecting
Default
, the factory settings are loaded.
Item
Short ASCII
Command
Values
Command Examples
UserSetLoad
LD
0: Default (Default)
1: User1
2: User2
3: User3
LD=[Param.]<CR><LF>
LD?<CR><LF>