![JAI GO-5000M-PMCL-1 User Manual Download Page 118](http://html1.mh-extra.com/html/jai/go-5000m-pmcl-1/go-5000m-pmcl-1_user-manual_3281399118.webp)
User Manual (Ver. 1.0) - Miscellaneous
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 118 -
Specifications
Description
Gamma
γ=0.45, 0.6, 1.0 (3 steps are available)
LUT
OFF: γ=1.0, ON=32 points can be set
Shading Compensation (Note1)
Flat field Block based (20 x 16 blocks)
HDR
4 settings, Level 1, 2, 3 and 4
Power supply
PoCL
Input range
DC +10 ~ +13V
Power
Consumption
3.24W Typical (Default setting /25°C Environment /DC +12V),
276mA/3.31W (Max)
4-pin Connector
(EP/UV models
only)
Input range
DC +10V
~
+25V
Power
Consumption
3.24W Typical (Default setting /25°C Environment /DC +12V),
276mA/3.31W (Max)
Lens mount
C mount, Rear protrusion of the lens is less than 10 mm.
Flange back
17.526 mm, Tolerance: 0 to -0.05 mm
Optical filter
Protection glass: Not provided
Operating temperature/
Humidity Performance guaranteed
-5°C to +45°C / 20 to 80% (No-condensing)
Storage Temp. / Humidity
-25°C to +60°C / 20 to 80% (No-condensing)
Regulation
CE (EN55032 Class A and EN55035), FCC Part15 SubpartB Class A, RoHS, WEEE
Housing Dimensions
29 x 29 x 52 mm (W x H x D) (excluding protrusion)
Weight
60g
Notes:
l
Note1) In 1X3-1Y type, if the width is set not to the multiple of 24, 1 or 2 pixels may not
contain video data.
l
Note 2) Performance guarantee is up to 1 second.
l
Note 3) Gaps in histogram may occur if more than +12dB of gain is applied.
l
Note 4) Approximately 5 minutes pre-heating is required to achieve these specifications.
l
Note 5) The above specifications are subject to change without notice.
Caution
: The performance specifications given for this camera have been verified for the
Operating Temperature range shown in the Specifications table. The camera may be able to
perform outside of the specified temperature range, but such performance has not been verified
and is therefore not guaranteed.
l
The camera's internal temperature sensor detects temperatures of 63 °C or less during
operation.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.