GO-5000M-PMCL / GO-5000C-PMCL
- 84 -
SequenceMode
GainBlue0
I Integer
R/W
SQPGB
1
Min
~
Max
-4533
17713 0
SQPGB1=[Param.]<CR>
<LF>
SQPGB1?<CR><LF>
(Bayer model only)
SequenceMode
GainBlue1
I Integer
R/W
SQPGB
2
Min
~
Max
-4533
17713 0
SQPGB2=[Param.]<CR>
<LF>
SQPGB2?<CR><LF>
(Bayer model only)
SequenceMode
GainBlue2
I Integer
R/W
SQPGB
3
Min
~
Max
-4533
17713 0
SQPGB3=[Param.]<CR>
<LF>
SQPGB3?<CR><LF>
(Bayer model only)
SequenceMode
GainBlue
(n-1)
I Integer
R/W
SQPGB
(n)
Min
~
Max
-4533
17713 0
SQPGB
(n)
=[Param.]<CR>
<LF>
SQPGB
(n)
?<CR><LF>
(Bayer model only)
SequenceMode
GainBlue
127
I Integer
R/W
SQPGB
128
Min
~
Max
-4533
17713 0
SQPGB
128
=[Param.]<CR>
<LF>
SQPGB
128
?<CR><LF>
(Bayer model only)
CommnadSequence
Index
I
Enumera
tion
R/W
C
SQI
Same
as
SequenceModeIndex
0
9
0
CSQI=[Param.]<CR><LF>
CSQI?<CR><LF>
CurrentSequence
Index
I
Enumera
tion
R/O
SQIDX
Same
as
SequenceModeIndex
0
9
0
SQIDX?<CR><LF>
SequenceReset
I
Enumera
tion
W/O SQRST
0
0
0
0
SQRST=[Param.]<CR><LF>
SequenceLutMode
I
Enumera
tion
R/W
SQLUT
0: Gamma
1: LUT
0
1
0
SQLUT=[Param.]<CR><LF>
SQLUT?<CR><LF>
MultiRoiIndexMax
I Integer
R/W
MRIM
Min
~
Max
1
5
1
MRIM=[Param.]<CR><LF>
MRIM?<CR><LF>
MultiRoiWidth
I Integer
R/W
MRW
Min
~
Max
8
2560
2560
MRW=[Param.]<CR><
L
F>
MRW?<CR><LF>