— 20 —
GO-2400M-PGE / GO-2400C-PGE
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
38 to 7999892 (µs) (1 µs/step)*
1
Exposure Auto
Off, Continuous
*1 The maximum value for [Exposure Time] varies depending on the value configured for the [Acquisition Frame
Rate Raw] setting.
Max. value for [Exposure Time] = [Acquisition Frame Rate Raw] value - 177 µs
The minimum value will differ depending on the [Pixel Format] setting value.
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Mode] to [On].
4
If necessary, change the [Exposure Auto] setting.
When not Controlling the Exposure Time
Configure the settings as follows.
Item
Setting value / selectable range
Exposure Mode
Off
The exposure will be performed with an exposure time equal to 1 / frame rate.
Note
•
[Exposure Time] will be disabled.
•
[Exposure Auto] cannot be used.