6.4.2. LVAL a-synchronous accumulation
With LS=1, the accumulation will start immediately after the trigger leading edge.
The exposure start delay is 9.7
µ
sec.
In EPS mode the exposure stops 0.5 L after the selected shutter time, (in number of LVAL).
In PWC mode the exposure stops 0.5 L after the trigger trailing edge.
A new trigger must not be applied before the previous frame is read out. (FVAL is low).
Minimum trigger interval
≥
( exposure time + 1 FVAL + 3 LVAL).
Important notes on using this mode.
In LVAL a-synchronous PWC mode there is no exposure jitter.
Fig. 23. LVAL a-synchronous accumulation in EPS mode
Fig. 24. LVAL a-synchronous accumulation in PWC mode