![JAI CV-M 9CL Operation Manual Download Page 15](http://html.mh-extra.com/html/jai/cv-m-9cl/cv-m-9cl_operation-manual_631537015.webp)
CV-M9 CL
1L = 50.96
µ
s
Fig. 20. Vertical timing for V binning.
6.3. Input/Output of Timing Signals
For settings, please refer to chapter “7. Configuring the Camera”
6.3.1. Input of external trigger
Input of external trigger signal can be via Camera Link (
TI=0
). Factory setting. Or as TTL on the
12 pin connector pin 10. (TI=1). Here it should be 4.0 Vp-p ±2.0 V from a 75
Ω
source. The
trigger input signal can be 75
Ω
terminated. Factory setting is TTL. For 75
Ω
termination
SW301.2 should be ON.
6.3.2. Output of EEN (XEEN)
The Exposure Enable signal EEN indicate that the accumulation is ongoing. It can be used for
controlling a strobe flash. The XEEN signal is found on the 12 pin connector pin 9. It is 4.0 Vp-p
from a 75
Ω
source. The EEN signal is also found in Camera Link.
- 14 -