CV-A50 IR
7.2. CV-A50 IR RS-232C command list.
Command Name
Format
Parameter
Remarks
A – General settings and useful commands
EB
Echo Back
EB=
[
Param.
]
<CR><LF> 0=Echo off
1=Echo on
Off at power up
ST
Camera Status request ST?<CR><LF>
Actual setting
HP
Online Help request HP?<CR><LF>
Command list
VN
Firmware version
VN?<CR><LF>
3 letter version
B – Timing and shutter related commands
SC
Scanning format
SC=
[
Param.
]
<CR><LF> 0=Interlaced
2=1/2 partial
1=Non-interl.
3=1/3 partial
Partial scanning is
not supported
TR
Trigger mode
TR=
[
Param.
]
<CR><LF> 0=normal
2=Pulse width
4=Long time
1=Edge
3=Frame delay
5=Start/stop
SM
Shutter mode
SM=
[
Param.
]
<CR><LF> 0=Normal 1=Programmab.
SH
Shutter speed
SH=
[
Param.
]
<CR><LF>
0=Off
0=1/50 (1/60)
2=1/250
4=1/1000
6=1/4000
1=1/100
1=1/125
3=1/500
5=1/2000
7=1/10000
Continuous only
Trigger modes and
Continuous
PE
Programmable expos.
PE=
[
Param.
]
<CR><LF> 0= No function
1023=1023.5H
1=1.5H
CCIR. H=64
μ
sec
EIA, H=63.5
μ
sec
*1)
C – Signals and polarity
FR
Accumulation
FR=
[
Param.
]
<CR><LF> 0=Field
1=Frame
PC
Pixel clock
PC=
[
Param.
]
<CR><LF> 0=no clock out
1=clock out
Should be off
when not used
TP
Trigger polarity
TP=
[
Param.
]
<CR><LF> 0= active low
1= active high
*2)
WP
WEN polarity
WP=
[
Param.
]
<CR><LF> 0= active low
1= active high
D – Gain and analogue signals setting
AS
AGC Switch
AS=
[
Param.
]
<CR><LF> 0=AGC off
1=AGC on
0= manual gain
AG
AGC Level
AG=
[
Param.
]
<CR><LF> 0=low 255=high
Range 0 to 255
GA
Manual gain Level
GA=
[
Param.
]
<CR><LF> 0=low 255=high
Range 0 to 255
RP
Rear Potentiometer
RP=
[
Param.
]
<CR><LF> 0=manual gain
1=rear potm.
SU
Setup Level
SU=
[
Param.
]
<CR><LF> 0=low 255=high
Range 0 to 255
WC
White clip Level
WC=
[
Param.
]
<CR><LF> 0=low 255=high
Range 0 to 255
GS
Gamma Select
GS=
[
Param.
]
<CR><LF> 0=gamma 1
1=gamma 0.45
E – Saving and loading data in EEPROM
LD
Load settings from
camera EEPROM
LD=
[
Param.
]
<CR><LF> 0=Factory data
2=User 2 area
1=User 1 area
3=User 3 area
Latest used data
area becomes
default at next
power up
SA
Save settings to
camera EEPROM
SA=
[
Param.
]
<CR><LF> 1=User 1 area
3=User 3 area
2=User 2 area
EA
EEPROM area request
EA?<CR><LF>
Return latest used
area
*1)
In normal non trigger mode (TR=0) PE<312 for CCIR and PE<262 for EIA. In trigger mode TR=1, EEN will not be correct if
PE>833.
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
!!
Do not try to use commands not shown in the list.