CV-A10 CL and CV-A70 CL
6.7. Save and Load Functions.
The following commands are for store and load camera settings in the camera EEPROM.
Load settings.
LD.
This command will load previous stored settings to the camera. 3 user settings can be stored in
the camera EEPROM. 1 factory setting is also stored in the camera. The settings stored in the
last used user area is used as default settings at power up.
Save Settings.
SA.
This command will store the actual camera settings to 1 of the 3 user area in the camera
EEPROM.
EEPROM Area.
EA.
If received, the camera will return
the last used user area number.
ST?
SM=2
SH=10
PE=3
TR=0
SL=0
LS=1
TI=0
TP=1
SC=3
VB=2
HB=2
BA=1
AS=1
AG=3
GA=3
BL=3
GS=1
VN?
VN=102
ID?
ID=ÿÿÿÿÿÿÿÿÿÿ
MD?
MD=CV-A10
UD?
UD=Eng. Sample #5
HP?
*** CV-A10 Help List *******************************
EB(echo back): 0=off, 1=on
ST(status request): return the all settings
VN(firmware version): return the version no. of firmware
ID(camera ID): return the camera ID (10 characters)
MD(model name): return the model name (max 10 characters)
UD(user ID): free text for user (max 16 characters)
SM(shutter mode): 0=preset shutter, 1=programmable exposure
2=auto shutter
SH(preset shutter): 0=off, 1=1/100, 2=1/120, 3=1/250, 4=1/500, 5=1/1000
6=1/2000, 7=1/4000, 8=1/8000, 9=1/15000, 10=1/25000
11=1/75000, 12=1/100000, 13=1/150000, 14=1/300000
PE(programmable exposure): 0 - 628
TR(trigger mode): 0=normal(continuous), 1=edge pre-select
2=pulse width control, 3=sensor gate control
SL(smearless): 0=off, 1=on
LS(LVAL synchronous accumulation): 0=sync., 1=async.
TI(trigger input): 0=camera-link, 1=hirose 12pin-10p
TP(trigger polarity): 0=active low, 1=active high
SC(scanning format): 0=full frame, 1=1/2 partial, 2=1/4, 3=1/8
VB(vertical binning): 0=off, 1=1/2 binning, 2=1/3, 3=1/4
HB(horizontal binning): 0=off, 1=1/2 binning, 2=1/3, 3=1/4
BA(bit allocation: 0=10bit, 1=8bit
AS(AGC select): 0=off(manual gain control), 1=on
AG(AGC/auto shutter reference): 1 - 1023
GA(manual gain level): -50 - +150
BL(black level): 0 - 255
GS(gamma select): 0=1.0(off), 1=0.45
LD(Load settings from EEPROM): 0=factory, 1=user1, 2=user2, 3=user3
SA(Save settings into EEPROM): 1=user1, 2=user2, 3=user3
*** Firmware Version 1.02 ***** Copyright(c) 2003 JAI Corporation *****
Fig. 35. Terminal printout of status, ID and Help for CV-A10 CL.
- 25 -