AD-131GE
72
10.6.12 Operation Mode and Functions matrix
1. Sync Mode = SYNC
Sensor
AD-131GE #0
AD-131GE #1
Auto Iris
output
Trigger Input
Trigger 1 : Valid
Trigger 2 : Invalid
Mode
Exposure
Time
JAI
Partial
Scan
Smear
Less
Enable
Exposure
Time
JAI
Partial
Scan
Smear
Less
Enable
1
Continuous
Yes
Yes
No
Yes
←
No
Yes(*)
2
Edge
Pre-select
(EPS)
Yes
Yes
Yes
Yes
←
←
No
3
Pulse Width
Control
(PWC)
Not
applicable
Yes
Yes
Not
applicable
←
←
No
4
RCT
—
—
—
—
—
—
—
5
Sequential
EPS
Yes
Yes
Yes
Yes
Yes
Yes
No
6
Delayed
Readout
EPS
Yes
Yes
Yes
Yes
←
←
No
7
Delayed
Readout
PWC
No
Yes
Yes
No
←
←
No
8
PIV mode
No
Yes
No
No
←
No
No
Note 1:
―
←”
means that the setting depends on AD-131GE #0
2. SYNC Mode = Async
Sensor
Bayer(channel1)
Monochrome(channel2)
Auto Iris
output
(note2)
Trigger Input
Trigger 1 : Valid
Trigger 2 : Invalid
Mode
Exposure
Time
JAI
Partial
Scan
Smear
Less
Enable
Exposure
Time
JAI
Partial
Scan
Smear
Less
Enable
1
Continuous
Yes
Yes
No
Yes
Yes
No
Yes (*)
2
Edge
Pre-select
(EPS)
Yes
Yes
Yes
Yes
Yes
Yes
No
3
Pulse Width
Control
(PW)
Not
applicable
Yes
Yes
Not
applicable
Yes
Yes
No
4
RCT
Yes
Yes
Automatically
ON
Yes
Yes
Automatically
ON
Yes(*)
5
Sequential
EPS
Yes
Yes
Yes
Yes
Yes
Yes
No
6
Delayed
Readout
EPS
Yes
Yes
Yes
Yes
Yes
Yes
No
7
Delayed
Readout
PWC
No
Yes
Yes
No
Yes
Yes
No
Note 1: ―
←”
means that the setting depends on AD-131GE #0.
Note2: RCT mode cannot be used in sync mode.
(*): The auto iris signal is selected by DIP switch SW700.
―
Iris Signal Output mode
‖
sets which
camera
video signal is used for the auto iris operation (CCD1=Camera #0, CCD2=Camera #1).
Summary of Contents for AD-131GE
Page 80: ...AD 131GE 79 ...
Page 81: ...AD 131GE 80 ...
Page 82: ...AD 131GE 81 ...
Page 84: ...AD 131GE 83 ...
Page 91: ...AD 131GE 90 Change History Month Year Revision Changes July 2012 1 0 New issue ...