AD-131GE
56
10.6.3.1 Timing chart
Following charts are examples if Sync mode is set to Sync and in full frame operation.
If Sync mode is set to Sync, the timing of trigger input is the same for both camera #0 and #1.
The exposure time can be set individually but the output timing of the video output is the
same.
Note: 2.8L to 3.8L after the exposure end of the longest exposure.
1 LVAL = 1660 clock (32.344
μ
s)
T1
T2
T3
T4
V-Binning OFF
0.2L(6.03
μ
s)
2.8L
~
3.8L
977L
966L
V-Binning ON
0.3L(11.86
μ
s)
1.8L
~
2.8L
489L
483L
Fig.41 Edge Pre-select LVAL asynchronous
t1(Exposure start delay)
t2
t3(Data output delay)
V-Binning Off
0.2L (6.03
μ
s)
2.8L
~
3.8L
10.8L
~
11.8L
V-Binning On
0.3L (11.587
μ
s)
1.8L
~
2.8L
5.8L
~
6.8L
Fig.42 Edge Pre-select LVAL asynchronous details
DATA out
FVAL
EEN
LVAL
Ext. Trigger
Exposure
Exposure Period
t1
t2
t3
Summary of Contents for AD-131GE
Page 80: ...AD 131GE 79 ...
Page 81: ...AD 131GE 80 ...
Page 82: ...AD 131GE 81 ...
Page 84: ...AD 131GE 83 ...
Page 91: ...AD 131GE 90 Change History Month Year Revision Changes July 2012 1 0 New issue ...