AD-081GE
52
10.5.3 Pulse Width Control (PWC) trigger mode
In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to
have a long time exposure. The maximum recommended time is <60 frames.
The accumulation is only LVAL async.
For timing details, refer to fig. 35 through fig. 40 and fig. 45 through fig.46.
To use this mode:
Set function:
Trigger mode
Pulse Width Control (PWC)
Readout mode
Sync, async,
Output Select
8-bit, 10-bit, 12-bit
Scanning
Full/Partial
Vertical binning
ON/OFF
Accumulation
LVAL async
Other functions
Input:
External Trigger
GigE I/F, Hirose 12-pin,Hirose 6-pin
Important Note:
1 The minimum duration of the trigger is 2L. The minimum period of trigger is as follows.
Sync mode:
Sync
Smearless OFF
Exposure time + 792L + 3L
Smearless ON
Exposure time( Min:199L+2L) + 792L + 2L
Sync mode:
Async
Smearless OFF
Exposure time + 792L + 3L
Smearless ON
Exposure time( Min:199L+2L) + 792L + 3L
FVAL(792L) is the FVAL period of continuous operation.
Fig.45 Pulse Width Control LVAL asynchronous