10.5. Operation Mode
AD-081GE has the following 8 operation modes and OB transfer and ROI modes.
1
Continuous
Pre-selected exposure
2
Edge Pre-Select Trigger
Pre-selected exposure
3
Pulse Width Control Trigger
Pulse width controlled exposure
4
Reset Continuous Trigger
Pre-selected exposure
5
PIV (Particle Image Velocimetry)
6
Sequence EPS
Pre-selected exposure
7
Delayed readout EPS
Pre-selected exposure
8 Delayed readout PWC
Pulse controlled exposure
9
Smearless
Effective for EPS and PWC
10 OB transfer mode
11 ROI mode
10.5.1 Continuous mode
For applications not requiring asynchronous external triggering, this mode should be used for
continuous operation.
For timing details, refer to fig. 33 through fig. 38.
To use this mode
Set function:
Trigger mode
Continuous
Sync mode
Sync, async, High transfer rate, High
dynamic range, High S/N
Output Select
8-bit, 10-bit, 12-bit
Scanning
Full/Partial
Vertical binning
ON/OFF
Shutter
Programmable, Exposure Time Abs,
Auto shutter
Programmable Shutter
0.5L to 792L (1L unit)
Other functions