AM-1600GE / AB-1600GE
51
Address
Function
R
ea
d/
Write
Size
Value / Range
of value
Description
Default
value
0xA13C
Test Stream
(Jumbo Packet
Check)
R
W
4
0=OFF
6=Moving Ramp
scale
0
0xA148
Blemish calibration
status and progress
R
W
4
31-24 bit:
0=completed
1=Too bright
2=Too dark
3=Time out error
4=Busy
5=Limt
6=Trigger is not
set as Normal
mode
23-16 bit:
Progress indication
(0% to 100%)
15 – 0 bit:
Error count of
verify
0xA148
0xA14C
Shading calibration
status and progress
R
W
4
31-24 bit:
0=completed
1=Too bright
2=Too dark
3=Time out error
4=Busy
5=Limt
6=Trigger is not
set as Normal
mode
23-16 bit:
Progress indication
(0% to 100%)
15 – 0 bit:
Error count of
verify
0xA1FC Temperature
R
4
0.0625ºC step,
Specified range:
-40 ºC
-55 ºC to 150 ºC
0xA200
LUT
Enable
R
W
4
0:OFF 1:ON
0
0xA300
User set save
W 4
1=User area1
Allows use to save all camera
settings. Last used area number
becomes new default.
1
0xA304
User set Load
W 4
0=Factory area
1=User area1
Allow the user to recall all
camera settings.
0
0xA308
Current User Set
Selector
R 4
0=Factory area
1=User area 1
0
0xA30C
Save Sequence
settings
W 4 1
only
1
Sequence function registers:
0xC000
Sequence Shutter 1
R
W
4
3 to 3327
Pre-program 1
st
shutter value
3327
0xC004
Sequence Shutter 2
R
W
4
3 to 3327
Pre-program 2
nd
shutter value
3327
Summary of Contents for AB-1600GE