AM-1600GE / AB-1600GE
14
Start Point
End Point
Length
Start Point
End Point
Length
6.4.2 12bit counter
Address
Internal Name
GenICam Name Access
Size
Value (Range)
0xB000 Counter Clock Choice
ClockSource
R/W
4
0x01: Pixel Clock
0xB004 Counter Dividing Value
ClockPreScaler
R/W 4
0x000: Bypass
0x001: 1/2 Dividing
0x002: 1/3 Dividing
|
0xFFF: 1/4096 Dividing
6.4.3
Pulse generators (19 bit x 2)
There are 2 pulse generators (designated 0 through 1) that can be used to create various
timing scenarios by programming start point, endpoint, length and repeats.
The following drawing is an example of settings.
FVAL is used for the input of Pulse Generator 0 and the clock after the rising edge of FVAL
counts 100 clocks for the high period of the pulse and 102 clocks for the pulse length.
As 2400 is for Clock Pre-scaler, the output of 12 bit counter is 25 KHz, which is 40µs.
Pulse Generator 0 creates a 4 ms pulse.
Fig.11 Example of Pulse Generator setting
The following shows JAI SDK Camera Control Tool for setting Pulse Generator.
Summary of Contents for AB-1600GE
Page 69: ......
Page 70: ...Changes history Month Year Revision Contents 1 0 New issue...