29
EN
B. 0-10V INPUT WITH WATER TEMPERATURE MONITORING
Off
The device is controlled via home automation. The unit starts as soon as there is
a 0-10V control signal and the set water temperature has been reached.
Configuration code : DPC.BR712 / DPC.BR722 / DPC.BR724
CO2
PC / RF
INPUT: 110-240VAC
OUTPUT: 24V
N L
Tw
To(4P)
Tr
Red not
connected
(200-240V - 50Hz)
N L
GND
0-10 V
B.1. FACTORY SETTINGS
The device is controlled via home automation.
The unit starts as soon as there is a 0-10V control
signal and the set water temperature has been reached.
The unit starts as soon as the water temperature is > 28°C and the control signal is 0-10V.
The unit starts as soon as the water temperature is < 18 ̊C and the control signal is 0-10V.
Enkel bij configuratiecode DPC.BR722 / DPC.BR724
Non-condensing cooling possible if water temperature setting is adjusted.
Activator speed in function of the incoming control signal.