6.2. ELECTRICAL CONNECTION
–
Non-compliant electrical wiring relieves Jaga NV of any liability with regard to damage or injury.
–
Make sure that the voltage and frequency of the electricity grid correspond to the data on the unit’s
data plate.
–
The available power is sufficient for the operation of the device.
–
If the unit is mounted on a metal surface, the earth-connection must be installed in accordance with
the local regulations. The earth conductor must be longer than the other lines in order for it to be
the last line to disconnect from the terminal block in case the lines start to disconnect.
–
The power cable section can handle the power that needs to be supplied.
1
3
2
0..10 V
SUPPL
Y
M
OTO
R
+ 24 V
GND
DC
DC
DC
[
[
blue
red
white
Option: Electrical connection to home automation - 0...1 0V
OPTION:
+ 0...10V
GND
0..10V
Domotica
230 V / 115 V
L
N
DC LO
DC ON
1 4
5 6
+ +
--
CODE: 7990.054/55/56/57
Netvoeding / Alimentation
Netzteil / Power supply
24 V
0...10 V
GND
+24 V DC