V03
JCAII
19
8-12 Error message
=EEPROM can not be read
=The calibration range can not be read
=Zero point is too high
=Zero point is too low
=Unstable zero point
=Overload
=
The last accumulation is more than the preset accumulation allowed.
8-13 Problem & Solution
Printer can not print out
Make sure the parameter P-05 is set correctly.
Make sure the parameter P-06 and P-07 match the printer.
If EZ-2P or BP-443D is being used, they should have download the printer format before.
HI & LO checking do not work
Make sure the function is enabled.
The value of LO is greater than HI.
No sound in HI & LO checking function
Make sure the parameter P-03 is set correctly.
Reset the time every time when the scale is turned on
Connect an optional RTC
How to check whether the printer is compatible to the scale
Under the parameter P-05, select “normal” printer.
Check the baud rate (P-06) and the data (P-07) is compatible to printer. If not, please change the
setting accordingly.
Under the normal weighing mode, press
to print. If the printer is able to print, it means
that this printer can replace the SH-24 printer.