6

operation

GAS CONNECTION

This appliance can be used with natural gas or LP gas. It is shipped from the factory adjusted for use with
the gas specified on the nameplate. (See page 4 of the User Manual, for the location of the nameplate.)
Please note that this appliance is not field convertible.

Shut off gas supply before removing an old
cooktop and leave it off until new installation is
completed.

Use only pipe joint compound that is approved for
use with liquified petroleum gases. Install a manual
shut-off valve in an accessible location in the gas
piping, external to the range for the purpose of
turning on or shutting off gas to the cooktop.

·

The appliance and its individual shut-off valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5kPa).

·

The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5 kPa). Check
incoming gas supply pressure and the manifold
pressure (after the regulator) using a manometer.
The required manifold pressure for natural gas is
5” water column and for LP is 10” W.C. The gas
supply line must be at least 1” W.C. (249 Pa)
above the manifold pressure and must not exceed
14” W.C. (3.5 kPa or 1/2 psig).

Check for gas leaks using soap-water solution. DO NOT USE OPEN FLAME TO CHECK FOR LEAKS.

(VERTICAL OR HORIZONTAL

CONNECTION)

Summary of Contents for RJCT30

Page 1: ...CAN CGA B149 2 Propane Gas Installa tion Code This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFA 7...

Page 2: ...instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier UNPACKING AND INSPEC...

Page 3: ...p for all models MODEL DIM A RJCT30 30 RJCT36 36 RJCT48 48 Safety Instructions RJCT3080A RJCT3680A RJCT3683A RJCT3681A RJCT4883A RJCT4881A OR ISLAND TYPE INSTALLATION FOR USE ONLY IN PENINSULA ISLAND...

Page 4: ...RJCT36 AND 60 INCHES FOR A RJCT48 Please refer to the chart for the recommended ventilating hood sizes For island installation the minimum clearances are 12 from rear wall 6 from side cabinets 18 abov...

Page 5: ...VERITICAL OR HORIZONTAL REGULATOR CONNECTION 3 4 NPT PIPE CONVERTIBLE BUILT IN A 120V 1 PH 60HZ 4AMPS 5 FT ELECTRICAL CORD SIDE TRIM 29 5 8 35 5 8 46 5 8 36 DSCT 36 DSCT 48 TOP COUNTER 48 DSCT 30 MODE...

Page 6: ...pliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa The appliance...

Page 7: ...hould be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug This appliance must be electrically grounded in accordance with local...

Page 8: ...8 RJCT3080A RJCT3680A RJCT3683A RJCT3681A RJCT4881A RJCT4883A...

Page 9: ...f heat at the HI setting DO NOT OPERATE THE BURNERS WITHOUT COOKWARE ON THE GRATES THE PORCELAIN ON THE GRATES MAY CHIP IF BURNERS OPERATE FOR AN EXTENDED PERIOD OF TIME WITHOUT COOKWARE ON GRATES The...

Reviews: