background image

5

INSTALLATION LAYOUT

Installation

installation

SIDE VIEW

3/4

1

24

9 1/2

9 1/2

9 1/2

ANGLE SUPPORT

  (SUPPLIED WITH APPLIANCE)

25

SIDE OF UNIT

WITH 3-PRONG ANGLED PLUG

REAR VIEW

3

3 1/2

PIPE

11

6 3/4

CORD

(VERITICAL OR HORIZONTAL

REGULATOR

CONNECTION)

3/4 NPT PIPE

CONVERTIBLE

BUILT-IN

A

120V/1-PH/60HZ/4AMPS

5 FT ELECTRICAL CORD

SIDE TRIM

29 5/8

35 5/8

46 5/8

36

DSCT-36

DSCT-48

TOP

COUNTER

48

DSCT-30

MODEL

30

A

B

''X''

SEE DETAIL

ANGLE SUPPORT

SUPPLIED WITH APPLIANCE

BACK GUARD

OPTIONAL

ISLAND BACK TRIM

STANDARD

DETAIL ''X''

REAR VIEW

(SHOWN WITH OPTIONAL BACK GUARD)

A

2

SIDE TRIM

24

A

23

B

RJCT30

RJCT48

RJCT60

Summary of Contents for RJCT30

Page 1: ...CAN CGA B149 2 Propane Gas Installa tion Code This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFA 7...

Page 2: ...instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier UNPACKING AND INSPEC...

Page 3: ...p for all models MODEL DIM A RJCT30 30 RJCT36 36 RJCT48 48 Safety Instructions RJCT3080A RJCT3680A RJCT3683A RJCT3681A RJCT4883A RJCT4881A OR ISLAND TYPE INSTALLATION FOR USE ONLY IN PENINSULA ISLAND...

Page 4: ...RJCT36 AND 60 INCHES FOR A RJCT48 Please refer to the chart for the recommended ventilating hood sizes For island installation the minimum clearances are 12 from rear wall 6 from side cabinets 18 abov...

Page 5: ...VERITICAL OR HORIZONTAL REGULATOR CONNECTION 3 4 NPT PIPE CONVERTIBLE BUILT IN A 120V 1 PH 60HZ 4AMPS 5 FT ELECTRICAL CORD SIDE TRIM 29 5 8 35 5 8 46 5 8 36 DSCT 36 DSCT 48 TOP COUNTER 48 DSCT 30 MODE...

Page 6: ...pliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa The appliance...

Page 7: ...hould be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug This appliance must be electrically grounded in accordance with local...

Page 8: ...8 RJCT3080A RJCT3680A RJCT3683A RJCT3681A RJCT4881A RJCT4883A...

Page 9: ...f heat at the HI setting DO NOT OPERATE THE BURNERS WITHOUT COOKWARE ON THE GRATES THE PORCELAIN ON THE GRATES MAY CHIP IF BURNERS OPERATE FOR AN EXTENDED PERIOD OF TIME WITHOUT COOKWARE ON GRATES The...

Reviews: