23
X
Operation of the ClearRay™ system is automatic and is de-
pendent upon activation of the circulation pump .
Q
Hydromassage activation
X
Press the key
once to activate the pump: the relative LED
will light up.
Press the key a second time, the pump will turn off (LED off ).
NOTES
If the pump is activated via the button, it will automatically shut
off after 20 minutes unless turned off earlier by the user.
Q
Underwater spotlight
(multicoloured light)
X
Press the key
to activate the spotlight located on the wall
of the tub (the LED comes on).
X
The spotlight will stay on for three hours, but it can be turned
off before that by pressing the key again.
Refer to the user’s man-
ual for the operation of the various sequences of colours.
Abnormal operating conditions
- alarm signals -
Alarms are indicated on the display, with the corresponding error code.
You will continue to see the code if the alarm condition persists.
X
Signals on display
- possible solution
X
“
LL
”
the level sensor (where present) identifies a low water level. The
term “LL” will appear on the display.
- Refill the water level.
X
“
HI
”
Excessive water temperature
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C . It is not pos-
sible to activate any function.
- If present, remove cover from spa.
- If the excessive temperature increase is due to sunlight, add
cold water to the spa.
When the temperature has dropped to below 43 °C, the spa should
re-activate automatically. If it does not, disconnect the power sup-
ply and contact an authorized Jacuzzi ® service centre.
X
“
Fr
”
Water temperature is too low.
The tub water temperature has fallen below 9 °C. However, all func-
tions remain active.
- Activate the heater.
When the temperature exceeds 10 °C, the error message disappears.
X
“
rPF
”
Defective temperature probe
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.