Operating Instructions
Now that your Santina spa is in place, you are probably eager to take advantage of its unique designed-in features—
especially the patented Jacuzzi Whirlpool Bath hydromassage performance. Besides being a beautiful addition to your
indoor decor or outdoor landscaping, your Jacuzzi
®
whirlpool spa will provide you with the ultimate in spa pleasure.
Basic Control Set-Up
The control set-up on your Santina spa is designed to give you fingertip control of the heater, light, air induction, and
whirlpool/filter pump and blower systems of your unit from inside or outside your spa. Follow the basic control operation
described on page 9 to familiarize yourself with the several functions of the control panels located on the top of the spa.
CAUTION
Do not turn on power to the spa unless it is filled with water to the normal water level. (See waterline indicator mark
on skimmer frame.) When the power is on, the built-in timer may activate the system even though the SYSTEM is
turned off at the control panel. If the spa’s motor/pump is actuated when there is insufficient water in the unit, the
circulation pump and heater could be irreparably damaged. Not heeding this caution will nullify the warranty. In
addition to damaging the unit, operating the spa with insufficient water could cause a fire.
SYSTEM CONTROL MODULE
• Using a garden hose, fill the spa with water to the water
line indicator mark on the skimmer frame (See page 20
for information on using the Water Rainbow spout as a
fill spout if desired.)
• At the house service panel, turn on the circuit breaker or
a switch that controls the electrical service to your spa.
(Make sure there is no other appliance on that circuit.)
• Open the skirt door giving access to the System Control
Module.
7
OPERATION
• Your spa is provided with a ground fault circuit interrupter
(GFCI). At initial start-up and at least once a month
thereafter, with power on, push the test button located on
the spa System Control Module. The reset button should
pop out. Push this button in to reset. If the interrupter fails
to operate in this manner, there is a ground current
flowing or a device malfunctioning, indicating the possi-
bility of electric shock. Turn off power and do not use
the spa until the source of the problem has been
identified and corrected.
HIGH TEMPERATURE SAFETY SWITCH
High temperatures above the thermostat range
will cause the high temperature safety switch to
trip and the system to turn off. See operating
instructions. When water temperature is less
than 100
°
F., reset by pressing the safety switch
reset button located on the cover of the heater
enclosure.
CAUTION: DO NOT BREAK DOOR SEAL;
OPENING DOOR VOIDS WARRANTY
THIS EQUIPMENT REQUIRES QUALIFIED SERVICE
PERSONNEL FOR PROPER REPAIR. CONTACT YOUR
JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE.
NO USER SERVICABLE PARTS BEHIND THIS DOOR.
CAUTION
This system is GFCI (Ground Fault Circuit Interrupter) pro-tected for your
safety. Bypassing the GFCI or tampering with the system in any way may
cause electrical shock, in-jury or death and will void the warranty. GFCI
protection does not extend to 230 VAC circuit conversion. If test indi-cates
that the GFCI is not functioning, DO NOT USE THE UNIT until the electrical
problem has been corrected. (See installation instructions.) TEST THE GFCI
ONCE A MONTH.
TEST PROCEDURE
Unit must be filled to proper water level and correct power supplied.
1. Push TEST button of GFCI.
2. RESET button should pop out. This should cut off power
to the system. CAUTION: if RESET button does not
pop out, or if RESET button does pop out and system
is still on, DO NOT USE YOUR SPA.
3. If the GFCI tests okay, restore power by pushing in the
reset button. The RESET button must be pushed until
it locks into place and remains depressed.
IF THE GFCI FAIL TO RESET PROPERLY, DO NOT USE
THE SPA! CONTACT A QUALIFIED ELECTRICIAN.
FLOW
SWITCH
TEMP.
SAFETY
SWITCH
INTERLOCK
SWITCH
LIGHT #1
LIGHT #2
M
o
n
d
a
y
T
u
e
s d
a y
Wednesd
ay
T
h
u
rs
d
a
y
F
rid
a
y
Sa
tu
rd
ay
Su
nd
a
y
Turn dial to correct time and day. Slide tabs
toward center for desired operating periods.
(One tab = 2 hrs.)
HEATER
BLOWER
JETS
MOTOR/
PUMP
FILTER
MOTOR/
PUMP
GFCI
TIMER
PLUG-IN
C0NNECTORS
FIELD WIRING BOX
(System Control Module P/N 876000
IMPORTANT: THIS UNIT IS FACTORY WIRED FOR USE
ON 115 VAC 30 AMP (3 WIRE) CIRCUIT ONLY.
Converting the electrical system to 230 VAC requires
a 4 wire 230 VAC 50 Amp circiut breaker; refer to the
instructions on the rear of this cover. The conversion
s h o u l d b e d o n e b y a q u a l i f i e d e l e c t r i c i a n .
REFER TO N.E.C. (NATIONAL ELECTRIC CODE AND
LOCAL CODES)