* Note: The skills and tools necessary for the safe repair of this spa require the services of qualified service personnel.
Contact your Jacuzzi Whirlpool Bath Authorized Service Agent or Dealer.
REMEDY
PROBABLE CAUSE
PROBLEM
G. Call and electrician or your
power company.
H. *
I.
*
J.
*
K.
*
A. Let cool for one hour. Motor
overload will reset; if problem
persists, see *Note.
B. Reset button on heater after
water has cooled; see *Note if
switch continues to trip.
C. *
D. *
E. Consult electrician to correct
wiring to unit.
G. Subnormal voltage.
H. Improper or defective wiring.
I. Locked shaft or impeller.
J. Motor windings burned out.
K. Defective starting switch
inside motor.
A. Motor overload condition.
B. High temperature safety
switch tripped.
C. Selector switch failure.
D. Relay failure.
E. Inadequate supply wiring.
10. Motor will not start.
(Continued)
11. Motor stops.
A. Power off.
B. ACCESSORY switch is OFF.
C. House circuit breaker tripped,
no power to system.
D. GFCI tripped.
E. Faulty motor.
12. Air Blower does not operate.
A. Timer is functioning.
13. Accessory Switch and system
switch in OFF position, but
motor and heater still
operating.
A. SYSTEM switch is not in
OFF position.
B. SYSTEM switch is in
HTR/FLTR position and spa is at
temperature set on thermostat.
C. Timer failure.
14. Timer will not activate spa.
A. Turn on power at service panel.
B. Select other function.
C. Reset circuit breaker.
D. Reset GFCI.
E. *
A. Turn SYSTEM switch to
OFF position.
B. Turn SYSTEM switch to OFF posi-
tion, or turn HEATER control
down. (If thermostat is already at
minimum setting, and spa is at
or above that temperature, timer
will not operate.)
C. *
A. Normal function, Turn timer to
an OFF position, or reset tabs
in off position.
19