WATER SUPPLY
DIRECT FROM THE WATER TAP
Use reinforced hose with minimum nominal diameter of 1/2" (13 mm).
FROM A TANK
- Before starting the cleaning, fill the suction hose with water or solution
to eliminate the air in the hose and in the pump head.
- It can be necessary to attach a non-return valve to the suction hose end
that will be under water or solution so that the hose is always filled with water or
solution.
This non-return valve is not supplied with the machine.
Suction hose
(Maximum length = 2.00 meters)
Tank
Water tap
ATTENTION
- The machine must be on the same level of, or on a level below, the tank.
Do not place the machine at higher than 1 meter above the water level.
- The machine is not supplied with the suction hose.
Non-return
valve
15
OPERATION
ASSEMBLING THE GUN-EXTENSION
Fit the gun extension (1) in the opening on
the gun body (2).
Press the extension against the gun and
rotate the extension to the right or left.
Then make sure the extension is properly secured.
PROCEDURES FOR USING
- Check the oil level and complete,
i f n e c e s s a r y , a c c o r d i n g t o
i n s t r u c t i o n s i n t h e s e c t i o n
"Maintenance".
- Before connecting the high pressure hose, pulse (swith on and off) the
motor several times to eliminate the air from the system.
This operation must be done
with the machine connected to a
water tap or tank until the jet
becomes continuous.
NOTE: These procedures must be
repeated when the hoses are
desconnected for storage.
1
2
Oil dipstick
Maximum level
Minimum level
18