CONTROLS 4
en-17
4.3
LCD DISPLAY _____________________________________________________________
The LCD displays current functional values for the
operation of the Eclipse 2 mower and sounds one of
three types of audible alerts. The LCD operates in one of
two modes, Operator Mode (Default), and Maintenance
Mode. Use of Maintenance mode requires a four digit pin
number.
Press either of the orange buttons (K or L) to change
screen display or change values. Push the right orange
button (K) to go forward in the display list or increase
setting value, and push the left orange button (L) to go
back in the display list or decrease setting value. The
black button (J) is used to select, reset, or change
values.
Figure 4B
Audible Alerts indicate one of three conditions detected
by the LCD Display and a corresponding message would
show on the display. A solid tone indicates low system
voltage. A fast beeping (2 per second) alert indicates an
over voltage condition. A slow beeping (1 every 3
seconds) alert indicates mower is in backlap mode.
Alert Displays: In addition to the standard displays for each mode, there are six displays that are used to alert the
operator/mechanic of a problem the needs to be corrected.
G
J
K
L
Alert Display
Alert Description
Low Voltage display is shown when system voltage drops below 42 Volts DC on Battery
powered mowers or 38 Volts DC on Gen-Set powered mowers, for 30 seconds and a solid tone
alarm will sound. Press the black button (J) to silence the alarm. Return mower to storage area
or install a fully charged battery pack. Reel motor will not operate with low voltage on the display.
Overvoltage/Check Voltage display is shown when system voltage is above 60 Volts DC and a
fast (2 per second) beeping alarm will sound. If not corrected, controller will shut down after 60
seconds. Check generator output before restarting system. [See Section 11.4].
Traction Motor Controller Fault display is shown when a problem is detected in the traction
motor controller. Traction motor will not operate until the problem is resolved. Return mower to
maintenance area for repair.
Traction Motor Fault display is shown when a traction motor short circuit is detected or the
traction motor current draw exceeds 30 Amps for one second. Traction motor will not operate
until the problem is resolved. Return mower to maintenance area for repair.
Reel Motor Controller Fault display is shown when a problem is detected in the reel motor
controller. Reel motor will not operate until the problem is resolved. Return mower to
maintenance area for repair.
Reel Motor Fault display is shown when a reel motor short circuit is detected or the reel motor
current draw exceeds 30 Amps for one second. Reel motor will not operate until the problem is
resolved. Return mower to maintenance area for repair.
WARNING
Turn reel switch off, release bail, turn key to off position, and disconnect battery connector before checking for
obstructions in reel.
!