9
07610-002-23-32-AC
Volts
Phase
Freq
Rinse Heater
Ratings
Total Amps
Typical Electrical
Circuit
208
1
60 Hz
N/A
12 A
15 A
230
1
60 Hz
N/A
12 A
15 A
208
3
60 Hz
N/A
12 A
15 A
230
3
60 Hz
N/A
12 A
15 A
Volts
Phase
Freq
Rinse Heater
Ratings
Total Amps
Typical Electrical
Circuit
415
3
60 Hz
12 kW
28 A
35 A
415
3
60 Hz
14 kW
30 A
40 A
208
1
60 Hz
12 kW@240 V
75 A
100 A
208
1
60 Hz
14 kW@240 V
82 A
110 A
230
1
60 Hz
12 kW@240 V
81 A
110 A
230
1
60 Hz
14 kW@240 V
90 A
125 A
208
3
60 Hz
12 kW@240 V
48 A
60 A
208
3
60 Hz
14 kW@240 V
52 A
70 A
230
3
60 Hz
12 kW@240 V
52 A
70 A
230
3
60 Hz
14 kW@240 V
57 A
80 A
460
3
60 Hz
12 kW@480 V
24 A
30 A
460
3
60 Hz
14 kW@480 V
26 A
35 A
TEMPSTAR HH & HH-E:
Volts
Phase
Freq
Rinse Heater
Ratings
Total Amps
Typical Electrical
Circuit
208
1
60 Hz
N/A
31 A
35 A
230
1
60 Hz
N/A
33 A
35 A
208
3
60 Hz
N/A
23 A
25 A
230
3
60 Hz
N/A
24 A
35 A
460
3
60 Hz
N/A
10 A
15 A
TEMPSTAR HH NB & TEMPSTAR HH LT:
TEMPSTAR HH S:
Volts
Phase
Freq
Rinse Heater
Ratings
Total Amps
Typical Electrical
Circuit
208
1
60 Hz
15.4 kW
87 A
110 A
230
1
60 Hz
15.4 kW
96 A
125 A
208
3
60 Hz
15.4 kW
55 A
70 A
230
3
60 Hz
15.4 kW
61 A
80 A
460
3
60 Hz
15.4 kW
28 A
35 A
TEMPSTAR HH VENTLESS:
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice.
Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2.
Typical fixed-trip circuit breaker sizes as listed in the NEC (latest edition).
NOTICE
i
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Summary of Contents for TempStar HH
Page 39: ...31 07610 002 23 32 AC 30 28 29 25 22 21 26 33 34 36 1 TOP MOUNT CONTROL BOX PARTS ...
Page 46: ...07610 002 23 32 AC 38 1 5 4 2 3 6 7 10 8 9 HOOD ASSEMBLY PARTS ...
Page 58: ...07610 002 23 32 AC 50 INLET PLUMBING PARTS 1 2 3 4 5 6 2 7 8 9 10 11 12 13 14 10 11 15 13 14 ...
Page 60: ...07610 002 23 32 AC 52 OUTLET PLUMBING PARTS 1 2 3 4 5 2 2 ...
Page 62: ...07610 002 23 32 AC 54 INLET PLUMBING HH E PARTS 1 13 9 2 3 4 5 6 7 5 8 10 11 12 2 14 ...
Page 64: ...07610 002 23 32 AC 56 OUTLET PLUMBING HH E PARTS 1 2 3 4 5 7 6 ...
Page 78: ...07610 002 23 32 AC 70 460 V MACHINE TRANSFORMER MOUNTING BOX PARTS ...
Page 79: ...71 07610 002 23 32 AC EXHAUST FAN CONTROL OPTION PARTS ...
Page 84: ...07610 002 23 32 AC 76 SCHEMATICS 208 230 V 50 60 HZ 1 PHASE ...
Page 85: ...77 07610 002 23 32 AC SCHEMATICS 460 V 50 60 HZ 3 PHASE ...
Page 86: ...07610 002 23 32 AC 78 SCHEMATICS LT NB 208 230 V 50 60 HZ 1 PHASE ...
Page 87: ...79 07610 002 23 32 AC SCHEMATICS LT NB 460 V 50 60 HZ 3 PHASE ...
Page 88: ...07610 002 23 32 AC 80 SCHEMATICS STEAM 208 230 V 50 60 HZ 1 3 PHASE ...
Page 89: ...81 07610 002 23 32 AC SCHEMATICS SDI OPTIONS ...
Page 90: ...07610 002 23 32 AC 82 SCHEMATICS DRAIN QUENCH OPTION ...