07610-002-10-23-V
11
INSTRUCTIONS
INSTALLATION
PRIMING CHEMICAL
FEEDER PUMPS
!
CAUTION
Chemical feeder pumps need priming when the machine is first installed or if the
chemical lines have been removed and air was allowed to enter.
CAUTION!
Water must be in the sump and wash tank before chemicals are dispensed.
1. Verify proper chemical tube with stiffener is in the proper container.
2. Use toggle switches on front of control box to prime each pump. There are three
priming switches:
3.
To prime the pumps, hold the switch in the momentary position until the
chemical is seen entering the sump.
• Detergent:
• Rinse-aid:
• Sanitizer:
4.
Detergent is dispensed during the wash cycle. The amount of detergent might
need to be adjusted depending on water quality and type of detergent.
5.
Rinse-aid is dispensed during the final rinse. The amount of rinse-aid
might
need to be adjusted depending on water hardness and results.
6.
Sanitizer is dispensed during the final rinse. The amount of sanitizer might need
to be adjusted depending on the concentration and type of sanitizer used.
7. Refer to next section for instructions on adjusting the chemical feeder pumps.
WARNING!
Some of the
chemicals used in
dishwashing might cause
chemical burns if they
come in contact with skin.
Wear protective gear when
handling these chemicals.
If any contact with skin
occurs, immediately
follow the treatment
instructions provided
with the chemicals.
!
WARNING