07610-002-10-23-V
10
INSTRUCTIONS
INSTALLATION
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Refer to the machine data plate for machine operating requirements, machine voltage,
total amperage, and serial number.
1. Remove control box top.
2. Install conduit into pre-punched holes in back of control box.
3.
Route power wires and connect to terminal block and grounding lug.
4.
Install service wires to the appropriate terminals as they are marked on terminal
block.
5. Install grounding wire into lug provided.
6. Apply anti-oxidation product to—and tighten—all power connections.
This machine may be operated with or without an exhaust hood depending on local
or state codes.
The thermostats on these
machines
have been set at the factory. They should only be
adjusted by authorized service personnel.
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power at the breaker
or disconnect switch
and lockout /tagout
in accordance with
procedures and codes.
VENTILATION
THERMOSTATS
1. Ensure power switch is in the OFF position and apply power to the
machine
.
2. Check the incoming power at terminal block and ensure it corresponds to voltage
listed on the data plate. If not, contact a qualified service agency to examine the
problem.
CAUTION!
Do not run the
machine
if voltage is too high or too low (refer to applicable
electrical codes)
.
3.
Shut off the service breaker and mark it as being for the
machine
.
4.
Advise all proper personnel of any problems and of the location of the service
breaker. Replace control box cover.
VOLTAGE CHECK
!
CAUTION
i
PREPARING
CHEMICAL FEEDER
PUMPS
These
machine
s are supplied with detergent, rinse-aid, and sanitizer chemical feeder
pumps.
Locate open ends of chemical tubes with the stiffeners and place each one in the
appropriate container.
• Red Tubing = Detergent • Blue Tubing = Rinse-aid
• White Tubing = Sanitizer
CAUTION!
Chlorine-based sanitizers can be detrimental to this machine if the chemical
solution is too strong. Contact chemical supplier to ensure the dispenser is set-up
correctly.
!
CAUTION