RINSE
HEATER
MODEL
VOLTS
PH HZ
RATINGS
AMPS
CIRCUIT
AJX-44CE
208
1 60 N/A
96.8 A
125 AMP
AJX-44CE
230
1 60 N/A
88.6 A
125 AMP
AJX-44CE
208
3 60 N/A
56.7 A
80 AMP
AJX-44CE
230
3 60 N/A
51.9 A
70 AMP
AJX-44CE
460
3 60 N/A
26.0 A
35 AMP
AJX-44CS
208
1 60 N/A
10.3 A
15 AMP
AJX-44CS
230
1 60 N/A
10.3 A
15 AMP
AJX-44CS
208
3 60 N/A
6.7 A
15 AMP
AJX-44CS
230
3 60 N/A
6.7 A
15 AMP
AJX-44CS
460
3 60 N/A
3.4 A
15 AMP
AJX-66CE
208
1 60 N/A
102.8 A
150 AMP
AJX-66CE
230
1 60 N/A
94.6 A
125 AMP
AJX-66CE
208
3 60 N/A
60.1 A
80 AMP
AJX-66CE
230
3 60 N/A
55.3 A
70 AMP
AJX-66CE
460
3 60 N/A
27.7 A
35 AMP
AJX-66CS
208
1 60 N/A
16.3 A
25 AMP
AJX-66CS
230
1 60 N/A
16.3 A
25 AMP
AJX-66CS
208
3 60 N/A
10.1 A
15 AMP
AJX-66CS
230
3 60 N/A
10.1 A
15 AMP
AJX-66CS
460
3 60 N/A
5.1 A
15 AMP
AJX-80CE
208
1 60 N/A
105.3 A
150 AMP
AJX-80CE
230
1 60 N/A
97.1 A
125 AMP
AJX-80CE
208
3 60 N/A
62.3 A
80 AMP
AJX-80CE
230
3 60 N/A
57.5 A
80 AMP
AJX-80CE
460
3 60 N/A
28.8 A
40 AMP
AJX-80CS
208
1 60 N/A
18.8 A
25 AMP
AJX-80CS
230
1 60 N/A
18.8 A
25 AMP
AJX-80CS
208
3 60 N/A
12.3 A
20 AMP
AJX-80CS
230
3 60 N/A
12.3 A
20 AMP
AJX-80CS
460
3 60 N/A
6.2 A
15 AMP
AJX-44 & AJX-54 Series Technical Manual 7610-003-60-98
Issued: 01-19-2009 Revised: 01-30-2009
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip cir-
cuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed
here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable
national and local codes. These numbers are provided in this manual simply for reference and may change without notice at
any given time.
AMPS
CIRCUIT
82.4 A
125 AMP
75.5 A
100 AMP
48.4 A
60 AMP
44.4 A
60 AMP
22.3 A
30 AMP
10.3 A
15 AMP
10.3 A
15 AMP
6.7 A
15 AMP
6.7 A
15 AMP
3.4 A
15 AMP
88.4 A
125 AMP
81.5 A
125 AMP
51.8 A
70 AMP
47.8 A
60 AMP
24.0 A
30 AMP
16.3 A
25 AMP
16.37 A
25 AMP
10.1 A
15 AMP
10.1 A
15 AMP
5.1 A
15 AMP
90.9 A
125 AMP
84.0 A
125 AMP
54.0 A
70 AMP
50.0 A
70 AMP
25.0 A
30 AMP
18.8 A
25 AMP
18.8 A
25 AMP
12.3 A
20 AMP
12.3 A
20 AMP
6.2 A
15 AMP
With 18kW Wash
Tank Heater
With 15kW Wash
Tank Heater
Summary of Contents for AJX-44 Series
Page 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 27: ...20 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 38: ...31 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 42: ...35 SECTION 4 TROUBLESHOOTING SECTION ...
Page 45: ...38 SECTION 5 PARTS SECTION ...
Page 92: ...85 SECTION 6 ELECTRICAL SCHEMATICS ...
Page 103: ...96 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 110: ...AJ 44T Series Technical Manual 7610 003 07 21 Issued 03 21 2006 Revised N A ...