The blower unit incorporates a number of safety measures to avoid the inadvertently
change in the flow conditions that include:
• The device has an audible alarm to indicate a blocked filter or low battery
• The device alarm activates for about 1 second when the blower unit is switched on,
and deactivates once the minimum operational flow rate is achieved. Please consider
the power-off state an abnormal situation while in use
• The switch for the air supply is recessed and so not possible to switch the air supply
off inadvertently
A Flow-Test-Unit is provided along with every ® PAPR unit to verify the right air
flow supply conditions. Please follow the instructions and recommendations provided in
this manual.
EN REGULATORY COMPLIANCE AND CE MARKS
P R SL-Filter AIRMAX:
Product code 40302
Filter colour coding:
White (background)
EU Manufacturer
Surewerx USA Inc
Elgin IL USA 60123
Compliance
EN
2941:1998+A1:2003+A2:2008
TH3 P R SL
Module B Audit conducted by
APAVE SUDEUROPE SAS
Notified Body 0082
CS60193 13322 MARSEILLE
CEDEX 16
France
Module C2
APAVE SUDEUROPE SAS
Notified Body 0082
CS60193 13322 MARSEILLE
CEDEX 16
CE marks
See labels on product
components
3
12941:1998+A1:2003+A2:2008