background image

  

or the US Department of Transport 
(DOT) for use in the USA. 

 
2.

 

The LP gas cylinder used for this 
appliance must not have a capacity 
larger than 20 lb. (9 kg): 

 

approximately 18” (46cm) high & 12” 
(30cm) diameter. 

 
3.

 

All LP gas cylinders used with this 
appliance should be inspected at every 
filling and re-qualified by a licensed 
service outlet at the expiry date (10 
years) in accordance with DOT (USA) 
and CTC (Canada) codes for LP gas 
cylinders. 

 
4.

 

All LP gas cylinders used with the 
appliance must be provided with a 
shut off valve terminating in a cylinder 
valve outlet No. 510, specified in the 
Standard for Compressed Gas Cylinder 
Valve Outlet and Inlet Connections 
(USA) ANSI / CGA-V-11977 (Canada) 
CSA B96. 

 

The cylinder supply system must be 
arranged for vapor withdrawal.  The 
cylinder must also include a collar to 
protect the cylinder valve.  As well, the 
cylinder valve must include a safety relief 
device having direct communication with 
the vapor space of the cylinder. 
 

H

ANDLING

 

 

1.

 

Government regulations prohibit 
shipping full LP gas cylinders.  You 
must take your new cylinder to an LP 
gas dealer for filling. 

 
2.

 

A filled LP gas cylinder is under very 
high pressure.  Always handle with 
care and transport in the 

upright

 

position.  Protect the valve from 
accidental damage. 

 
3.

 

Do not tip the LP gas cylinder while 
connecting it to the regulator.  Fasten 
the cylinder securely during transport, 
use and storage. 

 
4.

 

If the cylinder is tipped after it is 
connected to the regulator, shut off 
the gas, disconnect the regulator and 
have it checked before using it again. 

 

S

TORAGE 

 

1.

 

Store the LP gas cylinders outdoors in 
a well-ventilated area. 

 
2.

 

Do not store the LP gas cylinders in 
direct sunlight or near a source of heat 
or combustion. 

 
3.

 

If you intend to store your grill 
indoors, disconnect and remove the LP 
gas cylinder first.  Disconnected 
cylinders must have plugs installed 
and must not be stored in a building, 
garage or any other enclosed area. 

 
4.

 

Keep out of reach of small children. 

 
5.

 

When the LP gas cylinder is connected 
to the gas grill, the LP gas cylinder 
must be stored outside in a well-
ventilated area. 

 

6.

 

Keep the ventilation openings for the 
LP cylinder enclosure free and clear of 
debris. 

 
 
 
 
 
 
 

Summary of Contents for JG3

Page 1: ...xplosion Homeowners should retain these instructions C CO ON NT TE EN NT TS S A Message to our Customers 2 Safety 3 Installation 3 Clearances 4 LP Gas Cylinder 4 Specifications 4 OPD Equipped Cylinder 6 Hose and Regulator 6 Leak Testing 8 Gas Conversion 8 Maintenance 9 Lighting Instructions 11 Trouble Shooting 12 Warranty 13 Proudly Manufactured By Jackson Grills Inc G2 4970 Polkey Rd Phone 1 250 ...

Page 2: ...ue for quick reference If you need to obtain replacement parts for your Jackson Grill contact your local dealer NOTE It is normal for stainless steel surfaces to discolor due to high heat given off from the barbeque burners Please take the time to fill out and return the Ownership and Registration Card below It can be mailed to Jackson Grills Inc G2 4970 Polkey Road Duncan B C V9L 6W3 or fax 1 250...

Page 3: ...er appliance CAUTION 1 For outdoor use only 2 If stored indoors detach and leave cylinder outdoors 3 This appliance must not be operated unattended 4 Special care must be taken to keep small children away from heated surfaces ELECTRICAL CAUTION 1 If any accessory is used on this appliance with an external electrical power source the accessory when installed must be electrically grounded in accorda...

Page 4: ...upling Your grill is designed to be used with an LP gas cylinder equipped with the new QCC 1 Quick Closing Coupling system The QCC 1 system incorporates new safety features required by the Canadian Standards Steering Committee and the American National Standards Institute ANSI Gas will not flow until a positive connection has been made A thermal element will shut off flow of gas between 240 degree...

Page 5: ...ons prohibit shipping full LP gas cylinders You must take your new cylinder to an LP gas dealer for filling 2 A filled LP gas cylinder is under very high pressure Always handle with care and transport in the upright position Protect the valve from accidental damage 3 Do not tip the LP gas cylinder while connecting it to the regulator Fasten the cylinder securely during transport use and storage 4 ...

Page 6: ...harges of raw propane The new OPD causes a slower purge fill operation Some consumers have been advised by filling stations that these cylinders are defective This is not a defect Some propane filling stations may not be aware of this new device and its effects on the purge fill operation IDENTIFICATION To identify these cylinders the new OPD handwheel has been standardized to the shape shown HOSE...

Page 7: ...other hand turn the hand wheel clockwise until there is a positive stop Do not use tools Hand tighten only When making the connection hold the regulator in a straight line with the cylinder valve so as not to cross thread the connection 4 Leak test the connection See leak test 5 Refer to lighting instructions To avoid activating the Flow Limiting Device when lighting open the cylinder valve slowly...

Page 8: ...e appliance until the leak s is corrected NATURAL GAS INSTALLATIONS The outdoor cooking gas appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa The outdoor cooking gas appliance must be isolated from the gas supply by closing its individual manual shut off valve duri...

Page 9: ...all burners 5 Clean the outside of the burners with a wire brush and make sure all gas ports are clear Use a straight coat hanger to clear any obstructions 6 Use a flashlight to look into the venturi end of the burner to check for blockages If necessary use a straight coat hanger to clear any obstructions 7 Inspect and clean the venturi end of the burner by removing the venturi set screw on the en...

Page 10: ... and the flame tamers that are over each burner 2 Turn the burner you are lighting to high light and place a long match near the side gas ports of the burner 3 If the burner does not immediately light turn the valve to OFF Wait 5 minutes then repeat lighting procedures REAR BURNER LIGHTING If equipped 1 Light the rear burner by placing a long match next to the gas ports on the rear burner then tur...

Page 11: ...rner control to high position Remove warming rack Depress Igniter button and hold or light with a match Turn rear burner control to high positionand light with a match If ignition is not immediate turn burner control off Wait 5 minutes If ignition is not immediate turn burner control off Wait 5 minutes With left burner operating on high turn the center and or right burner to high ...

Page 12: ...essive great on sear plates and in drip pan Clean flame tamers and drip pan regularly Do not line pan with aluminum foil Refer to cleaning instructions Burners burn with yellow flame accompanied by smell of gas Possible spider web or other debris Thoroughly clean burner by removing See maintenance instructions Burner will not light with ignitor but will light with match Dead battery in ignitor Cha...

Reviews: