12
work area. This will ensure you do not re-install the propane orifices.
5. Using an approved thread sealant, replace the main burner orifices with the NEW natural gas
orifices supplied.
6. Before reinstalling the main burners make sure to close the air shutter on each burner half of what it
is set for propane use. When reinstalling the main burners ensure that the burner is properly
placed over the main burner orifice and reinstall the main burner cotter pin on the firebox rear wall.
7. Reinstall the flame diffusers and cooking grids.
ROTISSERIE BURNER CONVERSION
1. Using a # 2 Phillips screwdriver, undo the 4 screws that hold the back cover plate to the inner hood.
2. Once the cover has been removed use a 9 mm wrench to remove the rear burner orifice from the
rear burner. Place the propane rear burner orifice with the main burner propane orifices you
removed previously.
3. Install the new rear burner orifice using the wrench.
4. Reinstall the rear burner cover plate using the 4 screws previously removed.
NOTE:
There is NO air adjustment required when converting the rear burner from Propane Gas to
Natural Gas.
Remove the 3/8” flare fitting that attaches the propane hose from the Manifold block inside of the
pedestal and replace it with an approved 10’ Natural Gas neoprene hose.
REMEMBER TO LEAK CHECK ALL FITTINGS AND ORIFICES AFTER ALL OF THE CONVERSION
IS COMPLETED, LEAK CHECK ALL FITTINGS AND TEST FIRE ALL BURNERS TO ENSURE
PROPER, SAFE OPERATION.