ProTIG 500 AC/DC
Operating Manual
Page 23
17. Technical data
Power source
ProTIG 500 DC
ProTIG 500 AC
Supply voltage, 50/60 Hz
350V to 480V, 3 Phases
350V to 480V, 3 Phases
Mains fuse
32A
32A
Max. power draw
26 kVA, Imax = 40A, Ieff = 26A
28 kVA, Imax = 41A, Ieff = 26A
Kind of current
DC
AC
TIG
Electrode
TIG
Electrode
Set-point range Stepless
5- 500A
15- 400A
5- 500A
15- 400A
Operating voltage
10- 30V
20 - 36V
10- 30V
20 - 36V
Open circuit voltage
<13 V (reduced)
(max. 70V)
<13 V (reduced)
(max. 70V)
<13 V (reduced)
(max. 95V)
<13 V (reduced)
(max. 70V)
Duty cycle 40 % (40°C)
500A/ 30V
400A/ 36V
500A/ 30V
400A/ 36V
Duty cycle 60 % (40°C)
440A/ 27,6V
360A/ 34,4V
440A/ 27,6V
360A/ 34,4V
Duty cycle 100 % (40°C)
380A/ 25,2V
300A/ 32V
380A/ 25,2V
300A/ 32V
System of protection
IP 23
IP 23
Insulation class
F
F
System of cooling
F
F
Weight power source solo
43 kg
48 kg
Weight FG10/KG10 solo
62 kg
62 kg
Weight complete
105 kg
110 kg
Dimensions L x B x H (mm)
complete
1030 x 540 x 1000
1030 x 540 x 1000
Authorised for welding under
increased electrical hazard
Manufactured in accordance with
European Standards EN 60 974-1 and EN 60 974-10
Cooling unit KG 10
Supply voltage, 50/60 Hz
400V, 1 Phase
Mains fuse
16A
Max. power draw
300 VA
Power pump maximum
9l/min, 3,2 bar
Cooling power
1,1kW
System of protection
IP 23
Tank
8,5l
Manufactured in accordance with EN60974-2
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 26kVA (unit) + 30% = 34kVA. The generator for this unit must have 34kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.