INSTALLING THE HONEYWELL FAN AND LIMIT
CONTROL
Included in the accessory carton is a white sheet metal
bracket that is 8-1/4 inches high and 3-1/4 inches wide.
It has a 7/8” hole in it 6 inches from the bottom. Right
below the 7/8” hole are 2 screw holes. This bracket also
has 2 screw mounting holes on the bottom 1-1/4 inch
flange.
1. Place the sheet metal plenum on top of the warm air
duct opening.
2. Attach the fan and limit control mounting bracket to
the top of the furnace using sheet metal screws.
3. With the fan and limit control bracket up against the
sheet metal plenum, drill a 7/8” hole and two 1/8” holes
through the holes in the bracket and through the sheet
metal plenum using the bracket as a template.
4. Screw the mounting bracket clamp onto the bracket
and plenum with the 2 screws that are furnished.
5. Install the fan and limit control through the mounting
bracket and into the plenum.
6. Tighten the mounting bracket set screw into the fan
and limit control.
MOUNTING
CLAMP
Installation
25
Summary of Contents for SUPER SJ125
Page 11: ...3 1 2 4 5 6 7 8 9 Furnace Features SJ125 ...