INSTRUCTIONS FOR INSTALLING
FIELD CONTROLS TYPE R-C
BAROMETRIC DRAFT REGULATOR
DO NOT ATTACH DRAFT REGULATOR TO TOP OR BOTTOM OF
THE FLUE PIPE, NOR IN A ROOM SEPARATED FROM THE
FURNACE. BEST LOCATION IS AS CLOSE TO FURNACE AS
POSSIBLE.
PRE-MOUNTING SET UP INSTRUCTIONS
MAKE THE FOLLOWING ALTERATIONS BEFORE
MOUNTING DRAFT REGULATOR ON THE TEE
VERTICAL FLUE:
Adjustment weight must be in RIGHT HAND SLOT
(Marked “V”) in bracket on gate. See Fig. 7
The arrow on flap at bottom of gate must line up
with letter “V” on lower right part of gate. If it does
not, remove flap, turn over and snap on to gate
again.
Flap can be removed by inserting small screw
driver at the back side of the gate between the gate
and the flap, then pulling downward on flap.
HORIZONTAL FLUE:
Adjustment weight must be in LEFT HAND SLOT
(Marked “H”) in bracket on gate. See Fig. 8
The arrow on flap at bottom of gate must line up
with letter “H” on lower left part of gate. If it does
not, remove flap, turn over and snap on to gate
again.
Weight on “V”
side of bracket
Weight on “H”
side of bracket
IMPORTANT
A MANOMETER MUST BE USED TO
ACCURATELY ADJUST FLUE DRAFT
FIG. 7
FIG. 8
WARNING
NO DAMPER, HEAT SAVER, OR
AUTOMATIC VENT DAMPER DEVICE
SHOULD BE INSTALLED IN OR ON
SMOKE PIPE EXCEPT THE
BAROMETRIC DRAFT REGULATOR
Installation
31
WARNING
DO NOT CONNECT THIS FURNACE TO A
CHIMNEY SERVING ANOTHER
APPLIANCE
Summary of Contents for SUPER SJ125
Page 11: ...3 1 2 4 5 6 7 8 9 Furnace Features SJ125 ...
Page 13: ...1 2 3 4 5 6 7 Furnace Features BJ90 13 ...
Page 46: ...SUPER JACK SJ125 Exploded Views Parts Lists 46 ...
Page 48: ...BIG JACK BJ90 Exploded Views Parts Lists 48 ...
Page 53: ...Notes ...
Page 54: ...Notes Notes ...
Page 55: ...Notes ...