4.01 START UP
Before starting pump for the first time or
after servicing or maintenance work, check
the following - failure to do so could damage
equipment or cause injury to personnel.
• All pump head and mounting bolts are
tight.
• All pipe connections are secure.
• All guards, safety and protection devices,
are in place and effective.
• Flushing fluid, if required, is flowing - see
Section 2.10.
• All valves are open -
NEVER
run pump
against a closed valve.
• Pipes and pump head, if heated, are to
normal operating temperature.
• Pump and pipes are clear of welding flash
or other debris.
NEVER
use
Hy~Line
or
Ultima
pumps
to flush the system the first time. Flush
the whole system with suitable cleaning
agents before starting the
Hy~Line
or
Ultima
pump, using another more
suitable pump if necessary. Be aware
that heavy or metal debris tends to
collect at the lowest point in the system.
• Pump is correctly lubricated - see
Section 3.
• Motor is wired for correct direction of
rotation - see Figure 9.
When possible, start pump slowly and
increase speed gradually.
• Listen for unexpected noises.
• Check for leaks.
• Check that pump gives desired flow rate
at normal operating speed.
• Do not continue to run pump if fluid is not
flowing; dry running can damage seals -
see Section 2.10.
• Observe pump during first few hours of
operation - check for noises and
excessive heating of pump bearing
housing, i.e. if above 80°C (176°F), unless
pumping hot liquids when 110°C (230°F)
may be reached.
• If operating at high speeds or with hot
liquids, surface temperatures can exceed
50°C (122°F), safety labels may be
required to comply with local safety
regulations.
Page 16
Hy~Line
and
Ultima
Lobe Pumps
07/03
Figure 9.
Direction of
rotation -
viewed from
pump head.
(Principles
applies to all
mounting
orientations)
DIRECTION OF
DRIVE SHAFT
Clockwise
Counter
Clockwise
Clockwise
Counter
Clockwise
Horizontal Ports
Top Shaft Drive
Left to Right Right to Left
Left to Right Right to Left
Horizontal Ports
Bottom Shaft Drive
Right to Left Left to Right
Right to Left Left to Right
Vertical Ports
Bottom to
Top (up)
Top to Bottom
(down)
Top to Bottom
(down)
Bottom to
Top (up)
DIRECTION OF FLOW
VIEWED FROM
PUMP HEAD END
VIEWED FROM
DRIVE SHAFT END
Summary of Contents for Hy-Line
Page 41: ...07 03 Page 39 Hy Line and Ultima Lobe Pumps 7 00 MODEL NUMBER BUILD CODE...
Page 43: ...07 03 Page 41 Hy Line and Ultima Lobe Pumps 8 01 PARTS LIST...
Page 44: ...Page 42 Hy Line and Ultima Lobe Pumps 07 03 8 01 PARTS LIST CONTENTS OF KITS...
Page 45: ...Page 43 Hy Line and Ultima Lobe Pumps 07 03 8 02 Hy Line EXPLODED DIAGRAM...
Page 46: ...07 03 Page 44 Hy Line and Ultima Lobe Pumps 8 03 Ultima EXPLODED DIAGRAM...
Page 47: ...07 03 Page 45 Hy Line and Ultima Lobe Pumps 8 04 Hy Line 3 Size SECTIONAL VIEW...