Installation manual: Oasis security system JA-80K  

- 9 - 

 MKE51801

 

 

other intruder detector within 40 minutes, an alarm will be 
triggered. If the first triggered detector has a DEL reaction and 
it is not confirmed by any other detector, it will not trigger an 
alarm after the entrance delay has expired.

 

is set (armed). 
 

Exit delay beeps 

33x 

331 = YES      330 = NO 

YES 

The last 5 s faster 

Exit delay beeps while partially arming 

34x 

341 = YES     340 = NO 

NO 

The last 5 s faster 

Entrance delay beeps 

35x 

351 = YES      350 = NO 

YES  

Setting (arming) confirmation by wired-siren chirp 

36x 

361 = YES      360 = NO 

NO 

IW terminal only 

Siren always sounds during audible alarms  

37x 

371 = YES     370 = NO 

YES 

NO = siren only 
sounds if the system 
is completely set 
(armed) 

Wireless-siren alarms enabled (IW & EW) 

38x 

381 = YES     380 = NO 

YES  

Auto-bypass user approval via the 

∗ 

key 

If a detector is active during setting (arming), the system will 
automatically bypass it (them), immediately (390), or after 
keying in 

 (391)

 

39x 

391 = YES      390 = NO 

NO 

to confirm auto-
bypass while  exiting 
Service mode press # 
twice 

Final-door detectors 

If this function is used, then Exit & Entrance delay settings are 
multiplied by 30s. A triggered final-door detector extends the 
exit delay, de-triggering of the last final-door detector ends the 
exit delay.  

 

65x 

0=none, 1=detectors 01 to 05, 
2=detectors 46 to 50  

x = 0 

If multiple F. door 
detectors are used, 
then triggered 
state=any of them, 
non triggered state=all 
of them 

Partial setting (arming) or system splitting 

66x 

0 = unsplit system 
1 = partial setting (A, AB, ABC) 
2 = split system A, B & common 
section C (set if A & B are set)

 

unsplit 

 

Automatic Summer Time (Daylight Saving Time) 

680x 

6801 = YES     6800 = NO 

NO 

Changes internal 
clock + 1h on Apr.1 & 
-1h on Nov.1 

Tamper-signal differential indication - 

Tamper alarm in response to an increase in the 
number of triggered tamper sensors

 

681x 

  6811 = 

ignore permanently 

triggered tamper sensors, i.e. 

only react to an increase in 

the number of triggered 

tamper sensors

  

6810 = 

react with a tamper 

alarm to all triggered tamper 

sensors

 

X = 0 

Suppresses the  
indication of 
permanently triggered 
tamper sensors  

Operating the PG outputs using 

8 and 

682x 

6821 = YES     6820 = NO 

YES 

if yes then arrow keys 
can also operate PGX

Permanent alarm status display for a set system 

683x 

6831 = YES     6830 = NO 

NO 

suppresses the 3min. 
display timeout 

Tamper alarm if unset

 (disarmed)

 

684x 

6841 = YES     6840 = NO 

NO 

 

Recording PG output activation to memory 

685x 

6851 = YES     6850 = NO 

YES 

 

Engineer reset 

668x 

6851 = YES     6850 = N0

 

NO

 

 

Annual check requirement display 

If enabled then 12 months after exiting Service Mode an 
annual technical check request is displayed on the keypad unit 
(mobile phone & ARC notification optional)

 

690x 

6901 = YES     6900 = NO 

NO 

 

Only single alarm indication 

If enabled then another intruder alarm can not be triggered 
during an intruder alarm currently in progress.

 

691x 

6911 = YES     6910 = NO 

NO 

 

Setting (arming) by service code 

692x 

6921 = YES     6920 = NO 

NO 

only with the master 
code holder’s  
approval  

Audible panic alarm 

693x 

6931 = YES     6930 = NO 

NO  

Higher control-panel receiver-sensitivity 

Extends the communication range if there is no RF 
interference 

 

694x 

6940 = normal    6941 = higher 

normal  

Access by Code plus

 

Card

  

If enabled and there is a code and card assigned to the same 
user, then both of them must be presented for setting (arming) 
control (in any order).

 

695x 

6951 = Code+Card     

 6950 = Code or Card 

code or 

card 

 

Audible 24h intruder alarm

 

696x 

6961 = YES     6960 = NO 

YES  

Service mode only with S Master code 

697x 

6971 = YES     6970 = NO 

NO  

Summary of Contents for Oasis JA-80

Page 1: ...trol panel installation manual This manual is valid for control panel JA 80K version KE60108 printed on internal circuit board The control panel can be configured by a PC running ComLink software vers...

Page 2: ...WIRELESS SIREN ALARM ENABLED IW AND EW 13 12 22 AUTO BYPASS USER APPROVAL VIA THE KEY 13 12 23 FINAL DOOR DETECTORS 13 12 24 PARTIAL SETTING ARMING OR SYSTEM SPLITTING 14 12 25 AUTOMATIC SUMMER TIME D...

Page 3: ...two inputs are not used the two addresses can be used to enroll wireless devices Hard wired inputs are also provided by some wireless devices such as keypads door detectors and PIR movement detectors...

Page 4: ...e T 200 mA The control panel power supply is double insulated safety class 2 and does not incorporate a protective earth wire A double insulated power cable should be used with a minimum cross section...

Page 5: ...ered and an external warning will only follow if the entrance delay has been exceeded PGX PGY are a pair of terminals providing programmable outputs If an output is activated it switches to GND with a...

Page 6: ...r a while before pressing and holding the key the language can be selected for each individual keypad in the system i e different keypads can display different languages for example if foreigners are...

Page 7: ...siren can be activated by pressing its button A JA 80A outdoor siren can be activated for signal strength measurement by opening its cover thereby triggering its cover tamper switch Each installed dev...

Page 8: ...min 4 min 0 10s for testing PGX function 23x 7 on off 80 81 PGY function 24x x in an unsplit system 0 whole system set ABC PG on 1 any system part set PG on 2 AB set not C PG on 3 Fire alarm PG on 4 P...

Page 9: ...O NO Changes internal clock 1h on Apr 1 1h on Nov 1 Tamper signal differential indication Tamper alarm in response to an increase in the number of triggered tamper sensors 681x 6811 ignore permanently...

Page 10: ...nsplit then ABC hh hours mm minutes No action The scheduled actions will happen every day Changing the service code 5 NC NC NC new code 4 digits 8080 enter NC twice Go to maintenance mode 292 switches...

Page 11: ...led 2 6 0 disabled Factory default setting disabled Note In some places the system can be permanently or occasionally affected by radio interference e g by nearby radar stations TV transmitters etc In...

Page 12: ...ors 3 1 1 indication enabled 3 1 0 indication disabled Factory default setting indication enabled 12 15 Confirmation of intruder alarms To reduce the risk of false alarms and to comply with British st...

Page 13: ...l i e setting by keyfob does not trigger an approval request The automatic bypass of a detector will end after the detector has been de triggered for example if a door is closed If auto bypass user ap...

Page 14: ...es as two independent systems one being section A and the other section B There is also a common section C which is only set if section A and section B are set at the same time and is commonly used fo...

Page 15: ...eceive a notification earlier than a year later change the internal clock settings to the day and month you prefer before exiting Service Mode by entering 4hhmmDDMMYY and then re adjust the clock to t...

Page 16: ...ing the B key on the keypad e g setting arming the garage and the ground floor during the night ABC using the ABC key on the keypad e g to set the entire system when leaving the house In a split syste...

Page 17: ...n be enrolled instead If a device with production code xx x has already been enrolled to another address in the past and if the device is now enrolled to a new address then it will be moved to the new...

Page 18: ...the menu and then keypad text After editing keypad text using Comlink software all keypads including wireless ones must be connected to the digital bus to save the changes to the keypad units by clic...

Page 19: ...ard then it is possible to program whether both a code and card must be presented to the system for system access or whether only one of them is required see 12 37 The system does not allow the same c...

Page 20: ...mode as follows 1 The control panel must be in maintenance mode if not then enter 0 master code or card factory default 1234 while the system is totally unset 2 Press key 5 the display indicates Codes...

Page 21: ...register at www GSMLink cz 15 Basic guidance for installers 1 Create an installation plan that sufficiently covers the building to be protected 2 If the customer requests changes to the suggested conf...

Page 22: ...d and reports to the control panel Alternatively power the keypad with an AC adaptor to prevent sleep mode or install an indoor wireless siren type JA 80L to generate entrance delay beeps 17 Control p...

Reviews: