Digital communicator JA-65X 

3/7 

MFM53103 

Notes: 

Remote access connection can also be enabled by the 

alarm system user (regardless of the above setting) by entering 

89 while in the user mode, when the phone rings. If you use 

another telephone set on the same telephone line, it should be 

switched to the  tone dial mode. 

Factory setting:

 0 = never answer 

 

3.2 

Remote

 

access code setting 

sequence: 

07

 

In order to access the panel remotely, it is necessary to 

authorize the access with an 8-digit access code. This code is 

compared with the one programmed in the control panel. If the 

caller tries to access the panel with another code, the 

connection will be terminated immediately. A wrong code alarm 

will be triggered on the control panel after the 5

th

 unsuccessful 

attempt to dial in. Store your access code to the control panel by 

entering: 

0 7 xxxxxxxx

 

 

where: 

x x . . . . . x

 -  any 8 digits access code  

Factory setting:

 00000000 

 

Central monitoring station 

communication setting 

 

This part of the manual is intended only for specialists involved 

in monitoring.  We recommend to use a computer equipped with 

Comlink program for complete setting of the monitoring station 

communication. 

Changes of the setting can also be performed manually using 

the keypad: 

  Enter programming mode when disarmed (

F 0

  Service 

Code, factory default 6060), indicated by a “P“.  

To exit programming press the N key (“P“ will turn off). 

 

Central monitoring station communication parameters 

Sequence 

Description 

Factory default setting 

0 001 xx 

to 

0 198 xx 

Reporting codes table (see part 5) 

where: 

x

– 

9

,

 F0 = A

h

, F1 = B

h

 , F2 = C

h

, F3 = D

h

, F4 = E

h

, F5 = F

if 

00 

is set, the event is not reported 

 

00  

 

 

For all events 

 

0 2 xxxx 

Account ID code (4 digits, for 3/1 and 3/2 formats the structure is 0xxx) 

x

 = 

– 

(hexadecimal codes can be used too - see above) 

0000 

 

0 3 xy 

Protocol 

x

= Ademco Slow 

1

 = Ademco Fast 

2

 = Telemax 

3

 = Franklin 

=

 

Radionics 

2300 

 

5

 = Radionics 1400 

6

 = DTMF 2300 

7

 = Surgard 

8

 = Ademco 

Express 

9

 = Contact ID 

Format 

y

0

 = 3/1 (xxx R) 

1

 = 3/2 (xxx rc) 

2

 = 4/1/1 (xxxx Rn) 

3

 = 4/2 (xxxx rc) 

 

 

90 

 

 

Contact ID 

0 4 x 

Re-dialing pause, 

x

1 – 9 

(x 10 min.) 

10 minutes 

0 6 xx..xFy 

CMS phone numbers 

xx...x 

to memory 

y

 (1 and 2), pause = F0  

 

erased 

0 9 6060 

Communicator reset to factory default settings  

 

Notes:  

Some of the protocols are not standardized and some 

manufacturers  of Monitoring Station receivers use different 

parameters in some of their protocols. Therefore Jablotron 

cannot guarantee full compatibility with all Central Monitoring 

Station receivers. 

If the connection with the Monitoring Station is not available, 

the events are queued in the communicator’s memory and are 

transmitted in one burst as soon as the connection is 

established. All events are reported to the Monitoring Station in 

the same order as they happened. 

Once communication has started, it can not be interrupted 

unless the control panel is switched to the programming or to 

the user mode. For example, if the user causes a false alarm 

and then cancels it, both events are sent to Monitoring Station. 

Events occurring while the  control panel is in the 

programming or user mode are reported to the Monitoring 

Station after the closing of these modes. (They are stored in 

the memory and reported together with reporting codes 

describing the change of operation modes.) 

When the dialer is activated, the communication to the 

monitoring station has the highest priority (voice and SMS 

messages are sent later with lower priority). A User or Installer 

can interrupt the digital dialer communication by entering the 

User mode or Programming mode. Reset of the control panel 

has no influence to the digital communicator’s settings (it is 

reported to the Monitoring station as an event). 

The RESET of the digital communicator itself (sequence 0 

9 6060), the change  of the  Monitoring Station’s telephone 

numbers,  the change of an account number code or the 

change of a format setting will erase all the reporting codes 

queued in the communicator’s memory. However the  events 

remain stored in the control panel’s internal memory. 

Jablotron recommends use of the MS-350 monitoring 

station with ComGuard SW. 

 

 

4.1 

Reporting codes setting 

 

sequences:

 00 and 01

 

These sequences can be used to program the report codes for 

all possible events. Depending on the used protocol and 

format, different amounts of data should be entered. The 

complete report code programming table is shown in section 5. 

The setting sequence structure is as follows: 

0 x x x r c

 

 

where: 

xxx

   =   event number (from 001 to 198) 

rc  

=   report code (two digits). For 3/1 and 4/1/1 formats 

only the first digit of the report code is used (R). 

Codes should be entered in a hexadecimal 

format, with numbers higher than 9 beginning 

with the F key:  

A

h

 = F0  B

h

 = F1   C

h

 = F2   D

h

 = 

F3  E

h

 = F4   F

h

 = F5 

 

If the reporting code 00 is programmed, the event will not be 

reported to the Monitoring Station.

  

Notes:  

 

 

Abbreviation "Rc" is used in the report code programming 

table for the major events group. Only the first digit of this 

group of codes is transmitted when formats 3/1 or 

4/1/1are used. Other formats use both digits of the "Rc" 

and "rc" report codes. 

 

The Contact ID (CID) is an automatic protocol. If you enter 

any report code other than zero for a major event (Rc), all 

events of this type will be transmitted automatically 

including all details regarding the event source. Internal 

structure of the CID protocol is shown in part 1.1.  This 

protocol provides the most in-depth data for the monitoring 

station and its use is recommended by Jablotron. 

Summary of Contents for JA-65X

Page 1: ...will disengage all other devices hooked up to the phone line It will then one by one call all programmed numbers and play the user recorded message which corresponds to the event If the dialer makes...

Page 2: ...g method setting is also valid for Central monitoring station communications Factory default tone dialing 2 6 Telephone line checking sequence 9 9 x If this function is enabled the dialer will check r...

Page 3: ...s the connection is established All events are reported to the Monitoring Station in the same order as they happened Once communication has started it can not be interrupted unless the control panel i...

Page 4: ...tting sequence 04 If a dialer is triggered it attempts to make a connection alternating between the primary and the backup telephone number If it is not possible to make a connection after 8 attempts...

Page 5: ...rc 061 Zone alarm 4 rc 062 Zone alarm 5 rc 063 Zone alarm 6 rc 064 Zone alarm 7 rc 065 Zone alarm 8 rc 066 Zone alarm 9 rc 067 Zone alarm 10 rc 068 Zone alarm 11 rc 069 Zone alarm 12 rc 070 Zone alar...

Page 6: ...own fuse in control panel or other general failure 4 4 4 4 4 4 052 3 300 Control panel powering 4 148 3 300 No failure in the system 4 4 4 4 4 4 172 1 301 AC failure 4 173 3 301 AC switched on 4 054 1...

Page 7: ...e programmed in the control panel 8 digits optional bypassing of answering machine if this option was programmed in the control panel if the connection can not be established try to enter space after...

Reviews: